We have located links that may give you full text access.
Non-channeled Video Laryngoscopy as an Alternative to Conventional Laryngoscopy for Intubating Adult Patients in the Intensive Care Unit.
Curēus 2023 June
Background Endotracheal intubation in the intensive care unit (ICU) is often a risky procedure due to the emergency situation, unstable condition of the patient, and technical problems such as inadequate positioning. Several new techniques, such as video laryngoscopy, have been developed recently to improve the success rate of first-pass intubations and reduce complications. We conducted this study to compare a non-channeled reusable video laryngoscope BPL VL-02 (manufactured by BPL Medical Technologies, Bangalore, India) with a conventional laryngoscope for intubation of adult patients in the ICU. Methodology A total of 72 ICU patients were randomly allocated to be intubated with either conventional direct laryngoscopy via Macintosh blade (group A) or video laryngoscopy with BPL VL-02 (group B). All patients were intubated by the primary investigator and the assistant noted the following parameters: the total number of intubation attempts, total duration of intubation, assistance or alternative technique required, Cormack Lehane grading, and any complications. Results There was no significant difference in the Cormack Lehane grading, number of attempts, or complications between the two groups. On comparing the assistance required during intubation in patients, it was observed that four (11.11%) patients in group A and seven (19.44%) patients in group B needed backward, upward, and rightward pressure on the larynx assistance during intubation. In five (13.89%) patients in group B, Stylet was required during intubation. The difference was statistically significant (p = 0.0308). The video laryngoscopy group (group B) had a longer mean duration of intubation (64.36 ± 6.28 seconds) compared to group A (45.72 ± 11.45 seconds), and the difference was statistically significant (p < 0.0001). Conclusions Non-channeled video laryngoscope (BPL VL-02) is not a suitable alternative to conventional direct laryngoscopy with a Macintosh blade in terms of successful first-pass intubation, total duration of intubation, and assistance required.
Full text links
Related Resources
Trending Papers
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app