We have located links that may give you full text access.
Journal Article
Research Support, Non-U.S. Gov't
Outcomes of biologic versus synthetic mesh in CDC class 3 and 4 open abdominal wall reconstruction.
Surgical Endoscopy 2023 April
INTRODUCTION: Abdominal wall reconstruction (AWR) in a contaminated field is associated with an increased risk of wound complications, infection, and reoperation. The best method of repair and mesh choice in these operations have generated marked controversy. Our aim was to compare outcomes of patients who underwent AWR with biologic versus synthetic mesh in CDC class 3 and 4 wounds.
METHODS: A prospective, single-institution database was queried for AWR using biologic or synthetic mesh in CDC Class 3 and 4 wounds. Hernia recurrence and complications were measured. Multivariable logistic regression was performed to identify factors predicting both.
RESULTS: In total, 386 patients with contaminated wounds underwent AWR, 335 with biologic and 51 with synthetic mesh. Groups were similar in age, sex, BMI, and rate of diabetes. Biologic mesh patients had larger hernia defects (298 ± 233cm2 vs. 208 ± 155cm2 ; p = 0.004) and a higher rate of recurrent hernias (72.2% vs 47.1%; p < 0.001), comorbidities(5.8 ± 2.7 vs. 4.2 ± 2.4, p < 0.01), and a nearly fivefold increase in Class 4 wounds (47.8% vs. 9.8%, p < 0.001), while fascial closure trended to being less common (90.7% vs 96.1%; p = 0.078). Hernia recurrence was comparable between biologic and synthetic mesh (10.4% vs. 17.6%, p = 0.132). Wound complication rates were similar (36.1% vs. 33.3%, p = 0.699), but synthetic mesh had higher rates of mesh infection (1.2% vs 11.8%; p < 0.001) and infection-related resection (0% vs 7.8%, p < 0.001), with 66% of those synthetic mesh infections requiring excision. On logistic regression, wound complications (OR 5.96 [CI 1.60-22.17]; p = 0.008) and bridging mesh (OR 13.10 [CI 2.71-63.42];p = 0.030) predicted of hernia recurrence (p < 0.05), while synthetic mesh (OR 18.6 [CI 2.35-260.4] p = 0.012) and wound complications (OR 20.6 [CI 3.15-417.7] p = 0.008) predicted mesh infection.
CONCLUSIONS: Wound complications in AWR with CDC class 3 and 4 wounds significantly increased mesh infection and hernia recurrence; failure to achieve fascial closure also increased hernia recurrence. Use of synthetic versus biologic mesh increased the mesh infection rate by 18.6 times.
METHODS: A prospective, single-institution database was queried for AWR using biologic or synthetic mesh in CDC Class 3 and 4 wounds. Hernia recurrence and complications were measured. Multivariable logistic regression was performed to identify factors predicting both.
RESULTS: In total, 386 patients with contaminated wounds underwent AWR, 335 with biologic and 51 with synthetic mesh. Groups were similar in age, sex, BMI, and rate of diabetes. Biologic mesh patients had larger hernia defects (298 ± 233cm2 vs. 208 ± 155cm2 ; p = 0.004) and a higher rate of recurrent hernias (72.2% vs 47.1%; p < 0.001), comorbidities(5.8 ± 2.7 vs. 4.2 ± 2.4, p < 0.01), and a nearly fivefold increase in Class 4 wounds (47.8% vs. 9.8%, p < 0.001), while fascial closure trended to being less common (90.7% vs 96.1%; p = 0.078). Hernia recurrence was comparable between biologic and synthetic mesh (10.4% vs. 17.6%, p = 0.132). Wound complication rates were similar (36.1% vs. 33.3%, p = 0.699), but synthetic mesh had higher rates of mesh infection (1.2% vs 11.8%; p < 0.001) and infection-related resection (0% vs 7.8%, p < 0.001), with 66% of those synthetic mesh infections requiring excision. On logistic regression, wound complications (OR 5.96 [CI 1.60-22.17]; p = 0.008) and bridging mesh (OR 13.10 [CI 2.71-63.42];p = 0.030) predicted of hernia recurrence (p < 0.05), while synthetic mesh (OR 18.6 [CI 2.35-260.4] p = 0.012) and wound complications (OR 20.6 [CI 3.15-417.7] p = 0.008) predicted mesh infection.
CONCLUSIONS: Wound complications in AWR with CDC class 3 and 4 wounds significantly increased mesh infection and hernia recurrence; failure to achieve fascial closure also increased hernia recurrence. Use of synthetic versus biologic mesh increased the mesh infection rate by 18.6 times.
Full text links
Related Resources
Trending Papers
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app