Is Restoration of Hip Center Mandatory for Total Hip Arthroplasty of Protrusio Acetabuli?
Hip & Pelvis 2022 June
PURPOSE: While initial fixation using a press-fit of the acetabular cup is critical for the durability of the component, restoration of the hip center is regarded as an attributable factor for implant survival and successful outcome. In protrusio acetabuli (PA), obtaining both restoration of the hip center and the press-fit of the acetabular cup simultaneously might be difficult during total hip arthroplasty (THA). We tested the hypothesis that use of a medialized cup, if press-fitted, will not result in compromise of the implant stability and outcome after cementless THA of PA.
MATERIALS AND METHODS: A total of 26 cementless THAs of 22 patients with PA were reviewed. During THA, press-fit of the cup was prioritized rather than hip center restoration. A press-fit was obtained in 24 hips. A press-fit could not be obtained in the two remaining hips; therefore, reinforcement acetabular components were used. Restoration of the hip center was achieved in 17 cups; 15 primary cups and two reinforcement components; it was medialized in nine cups. Implant stability and modified Harris hip score (mHHS) between the two groups were compared at a mean follow-up of 5.1 years (range, 2-16 years).
RESULTS: Twenty-six cups; 17 restored cups and nine medialized press-fitted cups, remained stable at the latest follow-up. A similar final mHHS was observed between the restored group and the medialized group (83.6±12.1 vs 83.8±10.4, P =0.786).
CONCLUSION: Implant stability and favorable results were obtained by press-fitted cups, irrespective of hip center restoration. THA in PA patients showed promising clinical and radiological results.
MATERIALS AND METHODS: A total of 26 cementless THAs of 22 patients with PA were reviewed. During THA, press-fit of the cup was prioritized rather than hip center restoration. A press-fit was obtained in 24 hips. A press-fit could not be obtained in the two remaining hips; therefore, reinforcement acetabular components were used. Restoration of the hip center was achieved in 17 cups; 15 primary cups and two reinforcement components; it was medialized in nine cups. Implant stability and modified Harris hip score (mHHS) between the two groups were compared at a mean follow-up of 5.1 years (range, 2-16 years).
RESULTS: Twenty-six cups; 17 restored cups and nine medialized press-fitted cups, remained stable at the latest follow-up. A similar final mHHS was observed between the restored group and the medialized group (83.6±12.1 vs 83.8±10.4, P =0.786).
CONCLUSION: Implant stability and favorable results were obtained by press-fitted cups, irrespective of hip center restoration. THA in PA patients showed promising clinical and radiological results.
Full text links
Related Resources
Trending Papers
Renin-Angiotensin-Aldosterone System: From History to Practice of a Secular Topic.International Journal of Molecular Sciences 2024 April 5
Albumin: a comprehensive review and practical guideline for clinical use.European Journal of Clinical Pharmacology 2024 April 13
Revascularization Strategy in Myocardial Infarction with Multivessel Disease.Journal of Clinical Medicine 2024 March 27
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Interstitial Lung Disease: A Review.JAMA 2024 April 23
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app