We have located links that may give you full text access.
Memsorb™, a novel CO 2 removal device part II: in vivo performance with the Zeus IE ® .
Journal of Clinical Monitoring and Computing 2022 Februrary 2
Memsorb™ (DMF Medical, Halifax, Canada) is a novel device based upon membrane oxygenator technology designed to eliminate CO2 from exhaled gas when using a circle anesthesia circuit. Exhaled gases pass through semipermeable hollow fibers and sweep gas flowing through these fibers creates a diffusion gradient for CO2 removal. In vivo Memsorb™ performance was tested during target-controlled closed-circuit anesthesia (TCCCA) with desflurane in O2 /air using a Zeus IE® anesthesia workstation (Dräger, Lübeck, Germany). Clinical care protocols for using this novel device were guided by in vitro performance results from a prior study (submitted simultaneously). After IRB approval, written informed consent was obtained from 10 ASA PS I-III patients undergoing robot-assisted radical prostatectomy. TCCCA targets were 39% inspired O2 concentration (FI O2 ) and 5.0% end-expired desflurane concentration (FET des). Minute ventilation (MV) was adjusted to maintain 4.5-6.0% FET CO2 . The O2 /air (40% O2 ) sweep flow into the Memsorb™ was manually adjusted in an attempt to keep inspired CO2 concentration (FI CO2 ) ≤ 0.8%. The following data were collected: FI O2 , FET des, FI CO2 , FET CO2 , MV, fresh gas flow (FGF, O2 and air), sweep flow, and cumulative desflurane usage (Vdes). Vdes of the Zeus IE®-Memsorb™ combination was compared with historical Vdes observed in a previous study when soda lime (DrägerSorb 800 +) was used. Results are reported as median and inter-quartiles. A combination of manually adjusting sweep flow (26 [21,27] L/min) and MV sufficed to maintain FI CO2 ≤ 0.8% and FET CO2 ≤ 6.0%, except in one patient in whom the target Zeus IE® FGF had to be increased to 0.7 L/min for 6 min. FI O2 and FET des were maintained close to their targets. Zeus IE® FGF after 5 min was 0 [0,0] mL/min. Average Vdes after 50 min was higher with Memsorb™ (20.3 mL) compared to historical soda lime canister data (12.3 mL). During target-controlled closed-circuit anesthesia in patients undergoing robot-assisted radical prostatectomy, the Memsorb™ maintained FI CO2 ≤ 0.8% and FET CO2 ≤ 6.0%, and FI O2 remained close to target. Modest amounts of desflurane were lost with the use of the Memsorb™. The need for adjustments of sweep flow, minute ventilation, and occasionally Zeus IE® FGF indicates that the Memsorb™ system should preferentially be integrated into an automated closed-loop system.
Full text links
Related Resources
Trending Papers
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Executive Summary: State-of-the-Art Review: Unintended Consequences: Risk of Opportunistic Infections Associated with Long-term Glucocorticoid Therapies in Adults.Clinical Infectious Diseases 2024 April 11
Clinical practice guidelines on the management of status epilepticus in adults: A systematic review.Epilepsia 2024 April 13
Finerenone: From the Mechanism of Action to Clinical Use in Kidney Disease.Pharmaceuticals 2024 March 27
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app