We have located links that may give you full text access.
Journal Article
Research Support, Non-U.S. Gov't
Glycemic Outcome Associated With Insulin Pump and Glucose Sensor Use in Children and Adolescents With Type 1 Diabetes. Data From the International Pediatric Registry SWEET.
Diabetes Care 2021 May
OBJECTIVE: Insulin delivery methods, glucose-monitoring modalities, and related outcomes were examined in a large, international, diverse cohort of children and adolescents with type 1 diabetes from the Better Control in Pediatric and Adolescent Diabetes: Working to Create Centers of Reference (SWEET) -Registry.
RESEARCH DESIGN AND METHODS: Participants with type 1 diabetes of ≥1 year, aged ≤18 years, and who had documented pump or sensor usage during the period August 2017-July 2019 were stratified into four categories: injections-no sensor (referent); injections + sensor; pump-no sensor; and pump + sensor. HbA1c and proportion of patients with diabetic ketoacidosis (DKA) or severe hypoglycemia (SH) were analyzed; linear and logistic regression models adjusted for demographics, region, and gross domestic product per capita were applied.
RESULTS: Data of 25,654 participants were analyzed. The proportions of participants (adjusted HbA1c data) by study group were as follows: injections-no sensor group, 37.44% (8.72; 95% CI 8.68-8.75); injections + sensor group, 14.98% (8.30; 95% CI 8.25-8.35); pump-no sensor group, 17.22% (8.07; 95% CI 8.03-8.12); and pump + sensor group, 30.35% (7.81; 95% CI 7.77-7.84). HbA1c was lower in all categories of participants who used a pump and/or sensor compared with the injections-no sensor treatment method ( P < 0.001). The proportion of DKA episodes was lower in participants in the pump + sensor (1.98%; 95% CI 1.64-2.48; P < 0.001) and the pump-no sensor (2.02%; 95% CI 1.64-2.48; P < 0.05) groups when compared with those in the injections-no sensor group (2.91%; 95% CI 2.59-3.31). The proportion of participants experiencing SH was lower in pump-no sensor group (1.10%; 95% CI 0.85-1.43; P < 0.001) but higher in the injections + sensor group (4.25%; 95% CI 3.65-4.95; P < 0.001) compared with the injections-no sensor group (2.35%; 95% CI 2.04-2.71).
CONCLUSIONS: Lower HbA1c and fewer DKA episodes were observed in participants using either a pump or continuous glucose monitoring (CGM) or both. Pump use was associated with a lower rate of SH. Across SWEET centers, use of pumps and CGM is increasing. The concomitant use of pump and CGM was associated with an additive benefit.
RESEARCH DESIGN AND METHODS: Participants with type 1 diabetes of ≥1 year, aged ≤18 years, and who had documented pump or sensor usage during the period August 2017-July 2019 were stratified into four categories: injections-no sensor (referent); injections + sensor; pump-no sensor; and pump + sensor. HbA1c and proportion of patients with diabetic ketoacidosis (DKA) or severe hypoglycemia (SH) were analyzed; linear and logistic regression models adjusted for demographics, region, and gross domestic product per capita were applied.
RESULTS: Data of 25,654 participants were analyzed. The proportions of participants (adjusted HbA1c data) by study group were as follows: injections-no sensor group, 37.44% (8.72; 95% CI 8.68-8.75); injections + sensor group, 14.98% (8.30; 95% CI 8.25-8.35); pump-no sensor group, 17.22% (8.07; 95% CI 8.03-8.12); and pump + sensor group, 30.35% (7.81; 95% CI 7.77-7.84). HbA1c was lower in all categories of participants who used a pump and/or sensor compared with the injections-no sensor treatment method ( P < 0.001). The proportion of DKA episodes was lower in participants in the pump + sensor (1.98%; 95% CI 1.64-2.48; P < 0.001) and the pump-no sensor (2.02%; 95% CI 1.64-2.48; P < 0.05) groups when compared with those in the injections-no sensor group (2.91%; 95% CI 2.59-3.31). The proportion of participants experiencing SH was lower in pump-no sensor group (1.10%; 95% CI 0.85-1.43; P < 0.001) but higher in the injections + sensor group (4.25%; 95% CI 3.65-4.95; P < 0.001) compared with the injections-no sensor group (2.35%; 95% CI 2.04-2.71).
CONCLUSIONS: Lower HbA1c and fewer DKA episodes were observed in participants using either a pump or continuous glucose monitoring (CGM) or both. Pump use was associated with a lower rate of SH. Across SWEET centers, use of pumps and CGM is increasing. The concomitant use of pump and CGM was associated with an additive benefit.
Full text links
Related Resources
Trending Papers
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app