Influence of different infracardial positions of central venous catheters in hemodynamic monitoring using the transpulmonal thermodilution method.
Journal of Clinical Monitoring and Computing 2016 October
Hemodynamic measurements are often conducted by the transpulmonary thermodilution (TPTD)-based PiCCO(®)-system. This requires a central-venous (CVC) and a thermistor-tipped arterial catheter, usually placed in the femoral artery. In certain clinical situations, CVC devices have to be placed in the inferior vena cava. However, little is known about the influence of different CVC positions (i.e. ipsi- vs. contra-lateral to the arterial catheter) on the accuracy of the TPTD measurement results. In this prospective observational study surgical intensive care unit patients who had been inserted with CVCs either into the superior (CVCVCS) or the inferior vena cava (CVCinf) in addition to an arterial PiCCO(®)-catheter, were enrolled. Patients were then divided into two groups: Group I was provided with a CVC in the contralateral (CVCcontra) and Group II in the ipsilateral (CVCipsi) inferior vena cava. Thermodilution via injection of ice-cold saline was then performed via CVCsup and CVCinf. Bland-Altman analysis for cardiac index (CI), extra-vascular lung water index (EVLWI) and global end-diastolic volume index (GEDVI) were employed. Additional correction formulas for femorally assed parameters were determined. In a total of 28 patients, bias (limits of agreement) for measurements of CI in CVCcontra was found to be +0.2 (-0.4; +0.9) and +0.3 (-0.4; +1.0) L/min/m(2) in CVCipsi. GEDVI showed a bias of +274.8 (-47.3; +596.9) mL/m(2) in CVCcontra and +274.7 (-100.7; +650.1) mL/m(2) in CVCipsi. The mean EVLWI were 9.4 ± 4.3 mL/kg for EVLWIVCS and 10.7 ± 5.2 mL/kg for EVLWIinf. The LoA yielded at -3.4 and +6.1 mL/kg with a bias of +1.3 mL/kg. Percentage errors revealed clinically acceptable limits for CI and GEDVI, but not for EVLWI. Using TPTD via an infracardial central vein, measurements of CI showed high accuracy and precision while GEDVI measurements were precise with a lower accuracy, irrespective of the position of the infracardial CVC.
Full text links
Related Resources
Trending Papers
Mineralocorticoid receptor antagonists and reno-protection: What's the evidence & where do they fit? A guide for non-specialists.Diabetes, Obesity & Metabolism 2024 May 8
Angiotensin Receptor Blocker-Neprilysin Inhibitor for Heart Failure with Reduced Ejection Fraction.Pharmacological Research : the Official Journal of the Italian Pharmacological Society 2024 May 12
The Therapy and Management of Heart Failure with Preserved Ejection Fraction: New Insights on Treatment.Cardiac Failure Review 2024
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app