Endoscopic ultrasound-guided one-step transmural drainage of cystic abdominal lesions with a large-channel echo endoscope.

Endoscopy 2000 March
BACKGROUND AND STUDY AIMS: Transmual endoscopic drainage of peripancreatic fluid collections under endoscopic ultrasound (EUS) control has been reported. We evaluated a facilitated technique of one-step puncture and drainage using a new stenting device and a large-channel echo endoscope.

PATIENTS AND METHODS: EUS-guided transumural drainage of cystic lesions was attempted in six male patients. The drainage sites were duodenal in two instances and gastric in four. The lesions were pseudocysts, arising from chronic pancreatitis (n=2), and following acute pancreatitis (n=3), and one abscess. The median size of the pseudocysts was 50mm (range, 25 to 90). The punctures were carried out under direct EUS guidance, using a new echo endoscope with a 3.2-mm working channel. Transmural drainage was done using modified 7-F stents. Stents were inserted directly over a 1-mm puncture needle and their position was optimized using a 7-F pusher connected to the stent by a special construction. The stents were released by withdrawing the needle.

RESULTS: EUS-guided one-step drainage was technically successful in all 6 patients. It was possible to position the stents as desired, regardless of the location, size or pathogenesis of the target lesions. There were no complications associated with the endoscopic interventions. All the lesions, including two with putrid contents, had collapsed by the day following drainage. The stents were removed after a median period of 2 weeks (range 2-12). The cysts had completely resolved in four patients at follow-ups of 3-13 months (range). The patient with the gastric abscess underwent gastrectomy 2 weeks after stent extraction, because of a coincidental adenocarcinoma at the cardia, the abscess being resolved. One patient with necrotizing pancreatitis, who refused surgical treatment, died because of septic complications.

CONCLUSIONS: New large-channel echo endoscopes allow more aggressive endoscopic interventions to be carried out safely under direct EUS control. One-step drainage using the new 7-F stent-over-needle device was effective for six cystic lesions of variable origin.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app