We have located links that may give you full text access.
An institutional study on accuracy of freehand cervical C1 C2 screws placement by knock and drill technique in craniovertebral anomalous bony anatomy: An evaluation of more than 600 screws based on SGPGI screw accuracy criteria.
PURPOSE: To assess the accuracy of freehand cervical C1 C2 screws placement by knock and drill (K and D) technique in craniovertebral anomalous bony anatomy.
MATERIALS AND METHODS: From January 2017 to December 2022, 682 consecutive C1 C2 screws in 215 patients with craniovertebral junction (CVJ) anomalies were enrolled. All patients underwent posterior fixation with K and D technique without any fluoroscopic guidance. The patient's demographic details, clinical details, radiological details, major intraoperative events, and postoperative complications were noted. The screws malposition grades and direction on CT images in the axial and sagittal plane were defined as new per proposed "SGPGI accuracy criteria." All patients had a clinical evaluation at 3-month follow-up.
RESULTS: Total 682 C1, C2 screws were placed in 215 patients for CVJ anomalies using K and D technique. The accuracy of screws placement by freehand technique was 84.46% (576/682). So with technique explained the rate of malplacement in simple (16.35%) and complex (15.19%) groups were almost comparable and comparison difference was not significant ( P = 0.7005).
CONCLUSION: The freehand technique, as described, is effective in cases of anomalous bony anatomy, and it is mandatory in complex CVJ anomalies. The accuracy of screw placement and VA injury is comparable with major studies. This technique is supposedly cost-effective and less hazardous to both health-care workers and patients.
MATERIALS AND METHODS: From January 2017 to December 2022, 682 consecutive C1 C2 screws in 215 patients with craniovertebral junction (CVJ) anomalies were enrolled. All patients underwent posterior fixation with K and D technique without any fluoroscopic guidance. The patient's demographic details, clinical details, radiological details, major intraoperative events, and postoperative complications were noted. The screws malposition grades and direction on CT images in the axial and sagittal plane were defined as new per proposed "SGPGI accuracy criteria." All patients had a clinical evaluation at 3-month follow-up.
RESULTS: Total 682 C1, C2 screws were placed in 215 patients for CVJ anomalies using K and D technique. The accuracy of screws placement by freehand technique was 84.46% (576/682). So with technique explained the rate of malplacement in simple (16.35%) and complex (15.19%) groups were almost comparable and comparison difference was not significant ( P = 0.7005).
CONCLUSION: The freehand technique, as described, is effective in cases of anomalous bony anatomy, and it is mandatory in complex CVJ anomalies. The accuracy of screw placement and VA injury is comparable with major studies. This technique is supposedly cost-effective and less hazardous to both health-care workers and patients.
Full text links
Related Resources
Trending Papers
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app