We have located links that may give you full text access.
Clinical Outcomes of A New Hydrophobic Trifocal Intraocular Lens with Hydroxyethyl Methacrylate in Cataract Surgery: A Prospective Multicenter Study.
Korean Journal of Ophthalmology : KJO 2024 April 23
PURPOSE: To investigate the clinical outcomes of new hydrophobic trifocal intraocular lens (IOL) with hydroxyethyl methacrylate (HEMA) in the Korean population.
METHODS: This prospective, multicenter, and observational study evaluated the clinical outcomes of eighty eyes of 40 patients with age-related cataract underwent cataract surgery using CNWT (Clareon PanOptix). Assessment included monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA at 60cm), near visual acuity (UNVA at 40cm and 33cm), uncorrected defocus curves, questionnaires evaluating photic phenomena, spectacle independence and spectacle free satisfaction.
RESULTS: At 3-month postoperatively, mean uncorrected binocular visual acuities were 0.04, 0.04, 0.03 logMAR at far, intermediate, and near distances respectively. All patients achieved uncorrected binocular VAs of 0.2 logMAR or better. Monocular and binocular defocus curve indicated a mean VA of 0.2 logMAR or better at the defocus range of +1.0 D to - 3.0D (100 cm to 33 cm) and +1.0 D to - 3.5 D (100 cm to 28 cm). High spectacle independence was observed at all distances, with 37.5% patients reporting photic phenomena.
CONCLUSIONS: The Clareon PanOptix IOL has shown positive clinical outcomes, providing a viable option for cataract surgery. These lenses effectively address patients' visual needs, especially in intermediate and near distance tasks, reducing dependence on glasses.
METHODS: This prospective, multicenter, and observational study evaluated the clinical outcomes of eighty eyes of 40 patients with age-related cataract underwent cataract surgery using CNWT (Clareon PanOptix). Assessment included monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA at 60cm), near visual acuity (UNVA at 40cm and 33cm), uncorrected defocus curves, questionnaires evaluating photic phenomena, spectacle independence and spectacle free satisfaction.
RESULTS: At 3-month postoperatively, mean uncorrected binocular visual acuities were 0.04, 0.04, 0.03 logMAR at far, intermediate, and near distances respectively. All patients achieved uncorrected binocular VAs of 0.2 logMAR or better. Monocular and binocular defocus curve indicated a mean VA of 0.2 logMAR or better at the defocus range of +1.0 D to - 3.0D (100 cm to 33 cm) and +1.0 D to - 3.5 D (100 cm to 28 cm). High spectacle independence was observed at all distances, with 37.5% patients reporting photic phenomena.
CONCLUSIONS: The Clareon PanOptix IOL has shown positive clinical outcomes, providing a viable option for cataract surgery. These lenses effectively address patients' visual needs, especially in intermediate and near distance tasks, reducing dependence on glasses.
Full text links
Related Resources
Trending Papers
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app