We have located links that may give you full text access.
Unilateral dynamic balance assessment: The test-retest reliability of the OptoJump next drift protocol.
Journal of Bodywork and Movement Therapies 2024 January
BACKGROUND: The OptoJump Next Drift Protocol is a test designed to assess unilateral dynamic balance. Participants are required to perform a series of unilateral jumps from which left/right and forward/back displacement (Drift) is calculated.
OBJECTIVES: This investigation set out to establish the test-retest reliability of the OptoJump Next Drift Protocol.
METHOD: Twenty-six participants performed the OptoJump Next Drift Protocol on two separate occasions. Drift Area and Drift Area as a percentage of total available jump area were calculated for each leg.
RESULTS: Interclass Correlation Coefficients (ICC) indicated poor reliability for Drift Area and Drift Area as a percentage of total available jump area (right leg r = .44; left leg r = -0.20). However, 95% Limits of Agreement (LoA) suggested a stronger relationship. For Drift Area, between trial Mean Difference for the right leg was 50.87 cm2 (95% LoA = -227.57 - 328.87) and for the left leg it was 54.08 cm2 (95% LoA = -333.62 - 441.79). For Drift Area as a percentage of total available jump area, Mean Difference for the right leg was 0.56% (95% LoA = -2.44 - 3.65) and for left 0.60% (95% LoA = - 3.76-4.89).
CONCLUSIONS: Based on the 95% LoA data, the authors suggest that the OptoJump Next Drift Protocol does offer an acceptable level of reliability.
OBJECTIVES: This investigation set out to establish the test-retest reliability of the OptoJump Next Drift Protocol.
METHOD: Twenty-six participants performed the OptoJump Next Drift Protocol on two separate occasions. Drift Area and Drift Area as a percentage of total available jump area were calculated for each leg.
RESULTS: Interclass Correlation Coefficients (ICC) indicated poor reliability for Drift Area and Drift Area as a percentage of total available jump area (right leg r = .44; left leg r = -0.20). However, 95% Limits of Agreement (LoA) suggested a stronger relationship. For Drift Area, between trial Mean Difference for the right leg was 50.87 cm2 (95% LoA = -227.57 - 328.87) and for the left leg it was 54.08 cm2 (95% LoA = -333.62 - 441.79). For Drift Area as a percentage of total available jump area, Mean Difference for the right leg was 0.56% (95% LoA = -2.44 - 3.65) and for left 0.60% (95% LoA = - 3.76-4.89).
CONCLUSIONS: Based on the 95% LoA data, the authors suggest that the OptoJump Next Drift Protocol does offer an acceptable level of reliability.
Full text links
Related Resources
Trending Papers
Systemic lupus erythematosus.Lancet 2024 April 18
Should renin-angiotensin system inhibitors be held prior to major surgery?British Journal of Anaesthesia 2024 May
Autoimmune Hemolytic Anemias: Classifications, Pathophysiology, Diagnoses and Management.International Journal of Molecular Sciences 2024 April 13
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.