We have located links that may give you full text access.
Journal Article
Video-Audio Media
A Cost-Effective Delivery System for FloSeal During Endoscopic and Microscopic Brain Surgery.
World Neurosurgery 2016 June
OBJECTIVE: To share our experience with a new delivery system for the flowable hemostatic matrix, FloSeal, in endoscopic and microscopic skull base surgery.
METHODS: We prospectively analyzed the use of FloSeal with a hemostatic delivery system in transnasal endoscopic and microscopic skull base procedures performed at the authors' institution from January 1, 2015, to June 30, 2015. In all cases the number of aliquots was noted for the entire operation, and the total number of FloSeal ampules of 5 mL was also recorded.
RESULTS: Our device allowed controlled application of small amounts (0.5-1 mL) of FloSeal to the site of bleeding. This controlled application resulted not only in increased visibility during its application, but it also reduced the amount of FloSeal required during the procedure. We were able to use 5-10 applications per 5-mL ampule of FloSeal within an individual procedure. No procedure required more than one 5-mL ampule of FloSeal. Therefore, the use of our device results in a reduction of costs. Prior to the use of our device, we were often only able to use 1 vial of 5 ml of material for 1 or 2 applications, especially in transnasal endoscopic procedures when working along a deep corridor.
CONCLUSIONS: Our results indicate that our delivery device of FlowSeal can effectively control hemostasis by applying small amounts of FlowSeal to the site of bleeding. This results in increased visibility during hemostasis and a reduction of cost.
METHODS: We prospectively analyzed the use of FloSeal with a hemostatic delivery system in transnasal endoscopic and microscopic skull base procedures performed at the authors' institution from January 1, 2015, to June 30, 2015. In all cases the number of aliquots was noted for the entire operation, and the total number of FloSeal ampules of 5 mL was also recorded.
RESULTS: Our device allowed controlled application of small amounts (0.5-1 mL) of FloSeal to the site of bleeding. This controlled application resulted not only in increased visibility during its application, but it also reduced the amount of FloSeal required during the procedure. We were able to use 5-10 applications per 5-mL ampule of FloSeal within an individual procedure. No procedure required more than one 5-mL ampule of FloSeal. Therefore, the use of our device results in a reduction of costs. Prior to the use of our device, we were often only able to use 1 vial of 5 ml of material for 1 or 2 applications, especially in transnasal endoscopic procedures when working along a deep corridor.
CONCLUSIONS: Our results indicate that our delivery device of FlowSeal can effectively control hemostasis by applying small amounts of FlowSeal to the site of bleeding. This results in increased visibility during hemostasis and a reduction of cost.
Full text links
Related Resources
Trending Papers
Obesity pharmacotherapy in older adults: a narrative review of evidence.International Journal of Obesity 2024 May 7
Haemodynamic monitoring during noncardiac surgery: past, present, and future.Journal of Clinical Monitoring and Computing 2024 April 31
SGLT2 Inhibitors in Kidney Diseases-A Narrative Review.International Journal of Molecular Sciences 2024 May 2
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app