We have located links that may give you full text access.
Machine Learning to Improve Accuracy of Transcutaneous Bilirubinometry.
Neonatology 2024 April 30
INTRODUCTION: This study aimed to develop models for predicting total serum bilirubin by correcting errors of transcutaneous bilirubin using machine learning based on neonatal biomarkers that could affect spectrophotometric measurements of tissue bilirubin.
METHODS: This retrospective study included infants born at our hospital (≥36 weeks old, ≥2,000 g) between January 2020 and December 2022. Infants without a phototherapy history were included. Robust linear regression, gradient boosting tree, and neural networks were used for machine learning models. A neural network, inspired by the structure of the human brain, was designed comprising three layers: input, intermediate, and output.
RESULTS: Totally, 683 infants were included. The mean (minimum-maximum) gestational age, birth weight, participant age, total serum bilirubin, and transcutaneous bilirubin were 39.0 (36.0-42.0) weeks, 3,004 (2,004-4,484) g, 2.8 (1-6) days of age, 8.50 (2.67-18.12) mg/dL, and 7.8 (1.1-18.1) mg/dL, respectively. The neural network model had a root mean square error of 1.03 mg/dL and a mean absolute error of 0.80 mg/dL in cross-validation data. These values were 0.37 mg/dL and 0.28 mg/dL, smaller compared to transcutaneous bilirubin, respectively. The 95% limit of agreement between the neural network estimation and total serum bilirubin was -2.01 to 2.01 mg/dL. Unnecessary blood draws could be reduced by up to 78%.
CONCLUSION: Using machine learning with transcutaneous bilirubin, total serum bilirubin estimation error was reduced by 25%. This integration could increase accuracy, lessen infant discomfort, and simplify procedures, offering a smart alternative to blood draws by accurately estimating phototherapy thresholds.
METHODS: This retrospective study included infants born at our hospital (≥36 weeks old, ≥2,000 g) between January 2020 and December 2022. Infants without a phototherapy history were included. Robust linear regression, gradient boosting tree, and neural networks were used for machine learning models. A neural network, inspired by the structure of the human brain, was designed comprising three layers: input, intermediate, and output.
RESULTS: Totally, 683 infants were included. The mean (minimum-maximum) gestational age, birth weight, participant age, total serum bilirubin, and transcutaneous bilirubin were 39.0 (36.0-42.0) weeks, 3,004 (2,004-4,484) g, 2.8 (1-6) days of age, 8.50 (2.67-18.12) mg/dL, and 7.8 (1.1-18.1) mg/dL, respectively. The neural network model had a root mean square error of 1.03 mg/dL and a mean absolute error of 0.80 mg/dL in cross-validation data. These values were 0.37 mg/dL and 0.28 mg/dL, smaller compared to transcutaneous bilirubin, respectively. The 95% limit of agreement between the neural network estimation and total serum bilirubin was -2.01 to 2.01 mg/dL. Unnecessary blood draws could be reduced by up to 78%.
CONCLUSION: Using machine learning with transcutaneous bilirubin, total serum bilirubin estimation error was reduced by 25%. This integration could increase accuracy, lessen infant discomfort, and simplify procedures, offering a smart alternative to blood draws by accurately estimating phototherapy thresholds.
Full text links
Related Resources
Trending Papers
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app