Interlaboratory comparison of high-throughput protein biomarker assay quantifications for radiation exposure classification.

In the event of a widespread radiological incident, thousands of individuals will require rapid assessment of exposure using validated biodosimetry assays to inform clinical triage. In this scenario, multiple biodosimetry laboratories may be necessary for large-volume sample processing. To meet this need, we have developed a high-throughput assay for the rapid measurement of intracellular protein biomarkers in human peripheral blood samples using an Imaging Flow Cytometry (IFC) platform. The objective of this work was to harmonize and validate the reproducibility of our blood biomarker assay for radiation exposure across three IFC instruments, two located at Columbia University (CU) and the third at Health Canada. The Center for Radiological Research (CRR) at CU served as the central laboratory and reference instrument, where samples were prepared in triplicate, labeled with two radiation responsive leukocyte biomarkers (BAX and phosphor-p53 (Ser37)), and distributed for simultaneous interrogation by each IFC. Initial tests showed that significantly different baseline biomarker measurements were generated on each instrument when using the same acquisition settings, suggesting that harmonization of signal intensities is necessary. Subsequent tests harmonized biomarker measurements after irradiation by modulating laser intensity using two reference materials: unstained samples and standardized rainbow beads. Both methods generated measurements on each instrument without significant differences between the new and references instruments, allowing for the use of one master template to quantify biomarker expression across multiple instruments. Deming regression analyses of 0-5 Gy dose-response curves showed overall good correlation of BAX and p53 values across new and reference instruments. While Bland-Altman analyses indicated low to moderate instrument biases, ROC Curve analyses ultimately show successful discrimination between exposed and unexposed samples on each instrument (AUC values > 0.85).

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app