Eleven-year experience with composite graft replacement of the ascending aorta and aortic valve.

Between September, 1974, and December, 1985, 127 patients had replacement of the ascending aorta and aortic valve with a composite graft. Annuloaortic ectasia was the most common indication for operation (69 patients), followed by aortic dissection (51 patients). Twenty-four patients (19%) had the Marfan syndrome. Hospital mortality was 4.7%. Emergent operation for acute dissection was the only independent predictor of hospital death (p = 0.03). Reoperation for postoperative hemorrhage was required in 15 patients (11.8%) and for prosthesis-related complications (pseudoaneurysm, prosthetic endocarditis, technical problems, and valve thrombosis) in 16 patients (12.6%). Since we adopted a technique of preclotting the prosthesis with whole blood or albumin plus autoclaving and abandoned the inclusion technique, the reoperation rate has declined substantially. At 5 years, the actuarial freedom from reoperation for any reason on the ascending aorta or aortic valve for the 24 patients in whom this modification was used was 90% and for the remaining 103 patients, 73% (p = 0.17). No reoperations for pseudoaneurysms or technical problems were required in these 24 patients, whereas 10 reoperations for these complications were necessary in the other patients. The mean duration of follow-up was 54 months. The actuarial survival rate at 7 years for the entire group was 65%; for the patients with annuloaortic ectasia, 70%; for those with aortic dissection, 61%; for the patients with the Marfan syndrome, 57%. Actuarial freedom from operation on the remainder of the aorta at 7 years was 89%, but it was 78% for the subgroup with the Marfan syndrome. The satisfactory results with extended follow-up support the continued use of the composite graft technique as the preferred method of treatment for patients with annuloaortic ectasia or recurrent aneurysms of the sinuses of Valsalva and for patients with aortic dissection who require aortic valve replacement.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app