Add like
Add dislike
Add to saved papers

Comparison of thrombosis risk in an abdominal aortic dissection aneurysm with a double false lumen using computational fluid dynamic simulation method.

BACKGROUND: Aneurysms are associated with a mortality rate of 81% or more in cases of rupture.

OBJECTIVE: To analyse the haemodynamic indices and compare the thrombosis risk in a double false lumen abdominal aortic dissection aneurysm using computational fluid dynamics (CFD).

METHODS: Computer tomography angiography (CTA) imaging data were collected from a patient with a double false lumen abdominal aortic dissection aneurysm, and three different lesion morphology aneurysm models were established, double false lumen abdominal aortic dissection aneurysm, single false lumen abdominal aortic dissection aneurysm and saccular abdominal aortic aneurysm, in order to analyse the flow velocity, time-averaged shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT) of blood flow, and endothelial cell activation potential (ECAP).

RESULTS: All three aneurysms were in a low-flow state within the body, and the low-flow velocity flow in the proximal vessel wall extended to the right common iliac artery; the vortex intensity was more intense in the abdominal aortic dissection aneurysm than in the saccular abdominal aortic aneurysm. The risk area for thrombosis was concentrated in the expansion part of the aneurysm and the false lumen. The RRT and ECAP maxima of the double false lumen abdominal aortic dissection aneurysm were much greater than those of the single false lumen dissection aneurysm and saccular aortic aneurysm.

CONCLUSION: Low-velocity blood flow, high OSI, low TAWSS, high RRT, and high ECAP regions correlate with the risk of thrombosis. The double false lumen type of abdominal aortic dissection aneurysm had some specificity in this case. The risk of thrombosis in the patient was extremely high, and the largest risk zone was within the smaller false lumen, which could be because the smaller false lumen was connected to the true lumen by only one breach. The results of the study provide some guidance in the early screening and development of treatment plans.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app