We have located links that may give you full text access.
"Small is beautiful" A series of ileo-anal anastomoses performed with the 25 - mm circular stapler.
AIM: With the idea that a small diameter stapler should cause less sphincter trauma, we began to use the 25mm circular stapler to perform ileo-pouch-anal anastomosis (IPAA) and we report our experience.
MATERIAL OF STUDY: A retrospective study using a bowel function questionnaire and a quality of life questionnaire has been conducted on a group of patients who underwent IPAA using a 25mm stapler
RESULTS: We performed IPAA using a 25mm circular stapler in 37 patients. Postoperative mortality was nil and morbidity was 27%. One anastomotic stenosis occurred. Long term follow-up information was available on 28 patients. Mean follow-up was 70 months (range 8-177). Mean number of bowel movements was 4.5 (range 2-10, median 4.5) during the day and 0.9 (range 0-10, median 0) at night. Out of 28 patients, 19 (68%) were fully continent and 32% had occasional soiling, no one reported incontinence. All patients except one were able to withold their stool for more than 15 minutes. Daytime pad use was: never 86%, occasionally 3%, frequently 11%; nightime pas use was never 86%, occasionally 7% and frequently 7%. Bowel regulating drugs use was never 82%, occasionally 14%, regularly 4%. Evacuation difficulties were: never 75%, occasionally 21%, frequently 4%.
DISCUSSION: Our results compare favourably with the literature, which reports median bowel frequency 6-7.6/24h, 9.4- 33% urgency, 17-44% daytime soiling and 32-61% nighttime soiling.
CONCLUSIONS: Our results must be considered preliminary but we found the 25-mm stapler safe and adequate to perform IPAA.
KEY WORDS: IPAA, Ulcerative Colitis, Stapler, Function.
MATERIAL OF STUDY: A retrospective study using a bowel function questionnaire and a quality of life questionnaire has been conducted on a group of patients who underwent IPAA using a 25mm stapler
RESULTS: We performed IPAA using a 25mm circular stapler in 37 patients. Postoperative mortality was nil and morbidity was 27%. One anastomotic stenosis occurred. Long term follow-up information was available on 28 patients. Mean follow-up was 70 months (range 8-177). Mean number of bowel movements was 4.5 (range 2-10, median 4.5) during the day and 0.9 (range 0-10, median 0) at night. Out of 28 patients, 19 (68%) were fully continent and 32% had occasional soiling, no one reported incontinence. All patients except one were able to withold their stool for more than 15 minutes. Daytime pad use was: never 86%, occasionally 3%, frequently 11%; nightime pas use was never 86%, occasionally 7% and frequently 7%. Bowel regulating drugs use was never 82%, occasionally 14%, regularly 4%. Evacuation difficulties were: never 75%, occasionally 21%, frequently 4%.
DISCUSSION: Our results compare favourably with the literature, which reports median bowel frequency 6-7.6/24h, 9.4- 33% urgency, 17-44% daytime soiling and 32-61% nighttime soiling.
CONCLUSIONS: Our results must be considered preliminary but we found the 25-mm stapler safe and adequate to perform IPAA.
KEY WORDS: IPAA, Ulcerative Colitis, Stapler, Function.
Full text links
Related Resources
Trending Papers
Review article: Recent advances in ascites and acute kidney injury management in cirrhosis.Alimentary Pharmacology & Therapeutics 2024 March 26
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app