keyword
https://read.qxmd.com/read/38332924/an-unusual-complication-after-transcatheter-aortic-valve-implantation-a-case-report
#1
Alba Abril Molina, Mónica Fernández Quero, José E López Haldón, Manuel Villa Gil Ortega, José F Díaz Fernández
BACKGROUND: Ventricular septal defect (VSD) is an unusual complication of transcatheter aortic valve implantation (TAVI). The risk factors are not well understood but may include oversizing, calcification amount and location, left-ventricular chamber morphology, and valve-in-valve (ViV) procedures. Percutaneous treatment is challenging but is usually the preferred option. CASE SUMMARY: An 80-year-old woman with two previous surgical aortic valve replacements was admitted to our Cardiology Department for decompensated heart failure...
February 2024: European Heart Journal. Case Reports
https://read.qxmd.com/read/37077454/treating-mitroflow-dysfunction-by-means-of-an-open-valve-in-valve-perceval-implantation
#2
JOURNAL ARTICLE
Daniele Trombetti, Calogera Pisano, Claudia Altieri, Paolo Nardi, Sabrina Maria Ferrante, Laura Asta, Dario Buioni, Giovanni Ruvolo
No abstract text is available yet for this article.
March 2023: Polish Journal of Cardio-Thoracic Surgery
https://read.qxmd.com/read/36922040/hemodynamic-and-mid-term-outcomes%C3%A2-for%C3%A2-transcatheter-aortic-valve%C3%A2-replacement-in-degenerated-internally%C3%A2-stented-valves
#3
JOURNAL ARTICLE
Ahmed AlBadri, Jubin Joseph, Vivek Patel, Dhairya Patel, Ofir Koren, Wen Cheng, Hasan Jilaihawi, Raj Makkar
BACKGROUND: Valve-in-valve (ViV) transcatheter aortic valve replacement is indicated in patients undergoing repeat intervention for degenerative aortic valve bioprostheses. Patients with internally stented valves (ie, Mitroflow and Trifecta) are at high risk for coronary artery obstruction during ViV procedures because of valve design, as the leaflets are mounted outside the valve stent. OBJECTIVES: The aim of this study was to compare the hemodynamic and clinical outcomes of transcatheter aortic valve replacement within internally stented valves (ViV-IS) vs other surgical valves (ViV-OS)...
March 13, 2023: JACC. Cardiovascular Interventions
https://read.qxmd.com/read/36598643/externally-mounted-versus-internally-mounted-leaflet-aortic-bovine-pericardial-bioprosthesis-meta-analysis
#4
REVIEW
Yujiro Yokoyama, Yosuke Sakurai, Toshiki Kuno, Hisato Takagi, Shinichi Fukuhara
BACKGROUND: Recent studies reported higher-than-expected rates of early structural valve degeneration (SVD) and/or reoperation of externally mounted leaflet aortic bioprosthesis compared with others. This meta-analysis aims to compare the outcomes of bioprostheses with externally versus internally mounted leaflet design in patients who underwent surgical aortic valve replacement (SAVR). METHODS: MEDLINE and EMBASE were searched through November 2021 to identify comparative studies investigating outcomes following SAVR with either externally or internally mounted leaflet aortic bioprosthesis...
January 4, 2023: General Thoracic and Cardiovascular Surgery
https://read.qxmd.com/read/36534495/timing-of-bioprosthetic-valve-fracture-in-transcatheter-valve-in-valve-intervention-impact-on-valve-durability-and-leaflet-integrity
#5
JOURNAL ARTICLE
David Meier, Geoffrey W Payne, Leila B Mostaço-Guidolin, Rihab Bouchareb, Courtney Rich, Althea Lai, Andrew G Chatfield, Mariama Akodad, Hannah Salcudean, Georg Lutter, Thomas Puehler, Philippe Pibarot, Keith B Allen, Adnan K Chhatriwalla, Lars Sondergaard, David A Wood, John G Webb, Jonathon A Leipsic, Janarthanan Sathananthan, Stephanie L Sellers
BACKGROUND: Bioprosthetic valve fracture (BVF) can be used to improve transcatheter heart valve (THV) haemodynamics following a valve-in-valve (ViV) intervention. However, whether BVF should be performed before or after THV deployment and the implications on durability are unknown.  Aims: We sought to assess the impact of BVF timing on long-term THV durability. METHODS: The impact of BVF timing was assessed using small ACURATE neo (ACn) or 23 mm SAPIEN 3 (S3) THV deployed in 21 mm Mitroflow valves compared to no-BVF controls...
February 20, 2023: EuroIntervention
https://read.qxmd.com/read/36183748/excess-reintervention-with-mitroflow-prosthesis-for-aortic-valve-replacement-ten-year-outcomes-of-a-randomized-trial
#6
JOURNAL ARTICLE
Busra Cangut, Hartzell V Schaff, Rakesh M Suri, Kevin L Greason, John M Stulak, Brian D Lahr, Hector I Michelena, Richard C Daly, Joseph A Dearani, Juan A Crestanello
BACKGROUND: Current bioprostheses are considered to have improved durability and better hemodynamic performance compared with previous designs, but there are limited comparative data on late outcomes. METHODS: From 2009 through 2011, 300 adults with severe aortic valve stenosis undergoing aortic valve replacement (AVR) were randomly assigned to receive Edwards Magna, St Jude Epic, or Sorin Mitroflow bioprostheses (n = 100, n = 101, n = 99, respectively)...
September 30, 2022: Annals of Thoracic Surgery
https://read.qxmd.com/read/35990598/leaflet-disruption-of-viv-tavi-after-bioprosthetic-valve-fracture-leading-to-severe-aortic-regurgitation-a-case-report
#7
Edouard Ballout, Nicolas Combaret, Clément Riocreux, Géraud Souteyrand
BACKGROUND: Valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) has emerged as an alternative for the treatment of degenerated bioprosthetic valves (BPVs) for high surgical risk patients. However, this procedure often results in patient-prosthesis mismatch. BPV fracture is a novel technique to address this problem. From now, complications following BPV fracture are few. CASE SUMMARY: We present the case of a 84-year-old female with history of first surgical aortic BPV replacement with a Mitroflow Sorin 23 mm due to severe aotic stenosis in 2009...
August 2022: European Heart Journal. Case Reports
https://read.qxmd.com/read/35926920/impact-of-commissural-misalignment-on-hydrodynamic-function-following-valve-in-valve-intervention-with-the-acurate-neo
#8
JOURNAL ARTICLE
David Meier, Mariama Akodad, Andrew G Chatfield, Georg Lutter, Thomas Puehler, Lars Søndergaard, David A Wood, John G Webb, Stephanie L Sellers, Janarthanan Sathananthan
BACKGROUND: Limited evidence is available regarding valve-in-valve (VIV) intervention with the ACURATE neo transcatheter heart valve (THV). Low implantation has demonstrated leaflet interaction between the surgical bioprosthesis and the THV, leading to impaired hydrodynamic performance. It is unknown if commissural alignment (CA) can affect this phenomenon. Novel techniques have now been developed to achieve CA with the ACURATE neo THV. OBJECTIVES: The aim of this study was to assess the impact of commissural misalignment (CMA) on hydrodynamic function following VIV intervention with the ACURATE neo THV using a bench model...
August 8, 2022: JACC. Cardiovascular Interventions
https://read.qxmd.com/read/34333132/the-pathology-of-early-failure-in-mitroflow-pericardial-valve-bioprosthesis-12a-lx
#9
JOURNAL ARTICLE
Mila Della Barbera, Marialuisa Valente, Cristina Basso, Elena Pettenazzo, Gaetano Thiene
BACKGROUND: Limited mid-term durability of 12A/LX Mitroflow bioprosthesis has been reported. Aim of the study was to ascertain the pathologic substrates and possible mechanisms of structural valve deterioration in explants from animals and humans. METHODS: Nine aortic 12A/LX Mitroflow bioprostheses preserved in hypotonic solution and three aortic 12A/LX bioprostheses, preserved in isotonic solution, were explanted from juvenile sheep, mean time from implant 95.66 ± 36...
November 2021: Cardiovascular Pathology: the Official Journal of the Society for Cardiovascular Pathology
https://read.qxmd.com/read/34236798/comparison-of-postoperative-outcomes-of-sutureless-versus-stented-bioprosthetic-aortic-valve-replacement
#10
JOURNAL ARTICLE
Yesim Guner, Ayse Çiçek, Mehmet Karacalilar, Burak Ersoy, Mugisha Kyaruzi, Burak Onan
OBJECTIVE: Sutureless aortic valve replacement (Su-AVR) offers an alternative to supra-annular stented biological aortic prostheses. This single-center study aimed to compare early outcomes after aortic valve replacement with sutureless and conventional stented bioprostheses. METHODS: In this retrospective study, we analyzed 52 patients who underwent aortic valve replacement with sutureless and stented bioprostheses between January 2013 and October 2017. Sorin Perceval S sutureless valves were implanted in group 1 and Sorin Mitroflow stented bioprosthetic valves were used in group 2...
May 23, 2022: Brazilian Journal of Cardiovascular Surgery
https://read.qxmd.com/read/34221889/severe-aortic-regurgitation-of-early-degenerated-mitroflow-bioprosthesis-from-echocardiographic-diagnosis-to-treatment-with-valve-in-valve-transcatheter-aortic-valve-implantation
#11
Matteo Pernigo, Marco Triggiani, Marianna Adamo, Gian Franco Pasini
Valve-in-Valve transcatheter aortic valve implantation (ViV TAVI) is emerging as an effective therapeutic option for bioprosthetic valve failure. Recently, concern has been raised for early valve deterioration of Mitroflow (Sorin) aortic bioprosthesis, with the development of prevalent stenosis. We report cases of pure severe aortic regurgitation (AR) due to early and mid-term prosthesis degeneration. From June 2018 to October 2019, three patients were treated in our division for the new appearance of severe intraprosthetic regurgitation...
January 2021: Journal of Cardiovascular Echography
https://read.qxmd.com/read/34174404/mortality-and-reoperation-risk-after-bioprosthetic-aortic-valve-replacement-in-young-adults-with-congenital-heart-disease
#12
JOURNAL ARTICLE
Stephanie M Fuller, Michele J Borisuk, Lynn A Sleeper, Emile Bacha, Luke Burchill, Kristine Guleserian, Michel Ilbawi, Anees Razzouk, Takeshi Shinkawa, Minmin Lu, Christopher W Baird
Bioprosthetic aortic valve replacement (bAVR) in patients with congenital heart disease is challenging due to age, size and complexity. Our objective was to assess survival and identify predictors of re-operation. Data were retrospectively collected for 314 patients undergoing bAVR at 8 centers from 2000-2014. Kaplan-Meier estimation of time to re-operation and Cox regression were utilized. Average age was 45.2 years (IQR 17.8-71.1) and 30% were <21. Indications were stenosis (48%), regurgitation (28%) and mixed (18%)...
2021: Seminars in Thoracic and Cardiovascular Surgery
https://read.qxmd.com/read/34031022/outcomes-of-valve-in-valve-transcatheter-aortic-valve-implantation-with-and-without-bioprosthetic-valve-fracture
#13
JOURNAL ARTICLE
Christina Brinkmann, Mohamed Abdel-Wahab, Francesco Bedogni, Oliver Daniel Bhadra, Gaetan Charbonnier, Lenard Conradi, David Hildick-Smith, Faraj Kargoli, Azeem Latib, Nicolas M Van Mieghem, Darren Mylotte, Uri Landes, Thomas Pilgrim, Jan Stripling, Maurizio Taramasso, Didier Tchétché, Luca Testa, Holger Thiele, John Webb, Stephan Windecker, Julian Witt, Peter Wohlmuth, Joachim Schofer
BACKGROUND: Bioprosthetic valve fracture (BVF) is a technique to reduce gradients in valve-in-valve transcatheter aortic valve implantation (VIV-TAVI) procedures. Outcome of VIV-TAVI with BVF has not been compared with VIV-TAVI without BVF. AIMS: To evaluate the outcome of VIV-TAVI with BVF compared to VIV-TAVI without BVF. METHODS: In total, 81 cases of BVF-VIV-TAVI (BVF-group) from 14 centres were compared to 79 cases of VIV-TAVI without BVF (control-group)...
May 25, 2021: EuroIntervention
https://read.qxmd.com/read/33991385/bioprosthetic-valve-fracture-predictors-of-outcome-and-follow-up-results-from-a-multicenter-study
#14
MULTICENTER STUDY
Christina Brinkmann, Mohamed Abdel-Wahab, Francesco Bedogni, Oliver D Bhadra, Gaetan Charbonnier, Lenard Conradi, David Hildick-Smith, Faraj Kargoli, Azeem Latib, Nicolas M Van Mieghem, Mizuki Miura, Darren Mylotte, Uri Landes, Thomas Pilgrim, Friedrich-Christian Riess, Maurizio Taramasso, Didier Tchétché, Luca Testa, Holger Thiele, John Webb, Stephan Windecker, Julian Witt, Peter Wohlmuth, Alexander Wolf, Joachim Schofer
OBJECTIVES: To evaluate outcome and its predictors of bioprosthetic valve fracture (BVF) in patients undergoing valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). BACKGROUND: BVF is feasible and reduces transvalvular gradients in VIV-TAVR-procedures, but follow-up-data and information on factors influencing the outcome are missing. METHODS: The 81 cases of BVF-VIV-TAVR were collected from 14 international centers. RESULTS: Predominantly transcatheter heart valve (THV) was implanted first, followed by BVF...
October 2021: Catheterization and Cardiovascular Interventions
https://read.qxmd.com/read/33782703/balloon-expanding-transcatheter-aortic-valve-implantation-for-degenerated-mitroflow-bioprostheses-clinical-and-echocardiographic-long-term-outcomes
#15
JOURNAL ARTICLE
Victor X Mosquera, Alberto Bouzas-Mosquera, Yago Vilela-González, Carlos Velasco, Jorge Salgado-Fernández, Ramón Calviño-Santos, Nicolás Vázquez-González, José M Vázquez-Rodríguez, José M Herrera-Noreña
OBJECTIVES: This study aims to analyse the risks associated with valve-in-valve procedures for treating structural valve deterioration in Mitroflow bioprostheses, as well as to determine the impact of the original Mitroflow size on the patients' long-term outcomes. METHODS: Between January 2012 and September 2019, 21 patients (61.9% males; mean age 82.4 ± 5.4 years) were treated for Mitroflow deterioration with valve-in-valve procedures (12 transapical and 9 transfemoral)...
July 26, 2021: Interactive Cardiovascular and Thoracic Surgery
https://read.qxmd.com/read/33723975/the-bailout-transseptal-approach-during-valve%C3%A2-in%C3%A2-valve-transcatheter-aortic-valve-implantation-with-difficult-crossing-of-the-degenerated-mitroflow-bioprosthetic-valve
#16
JOURNAL ARTICLE
Damian Hudziak, Andrzej Ochała, Radosław Gocoł, Michał Kozłowski, Wojciech Wojakowski
No abstract text is available yet for this article.
April 23, 2021: Kardiologia Polska
https://read.qxmd.com/read/33601185/the-effect-of-clinically-recommended-evolut-sizes-on-anchorage-forces-after-basilica
#17
JOURNAL ARTICLE
Halit Yaakobovich, Romina Plitman Mayo, Uri Zaretsky, Ariel Finkelstein, Dar Weiss, Gil Marom
Coronary artery obstruction (CAO), a fatal complication of transcatheter aortic valve replacement (TAVR), is commonly found after Valve-in-Valve implantation inside a degenerated bioprosthetic valve. Leaflet laceration (BASILICA technique) has been proposed to prevent CAO and to potentially reduce the risk of leaflet thrombosis. We have previously demonstrated that this technique can reduce the anchorage forces of the TAVR device, which may lead to future complications. In this short communication, we hypothesize that the anchorage force reduction can be minimized by implanting a TAVR with a larger diameter, if two sizes are clinically recommended...
March 30, 2021: Journal of Biomechanics
https://read.qxmd.com/read/33601181/impact-of-basilica-on-the-thrombogenicity-potential-of-valve-in-valve-implantations
#18
JOURNAL ARTICLE
Romina Plitman Mayo, Halit Yaakobovich, Ariel Finkelstein, Shawn C Shadden, Gil Marom
Subclinical leaflet thrombosis is becoming a major concern in valve-in-valve procedures, whereby a transcatheter aortic valve device is deployed inside a failed bioprosthetic surgical valve. Blood flow stagnation and prolonged residence times in the neo-sinuses have been suggested as possible explanations for leaflet thrombosis. The BASILICA technique, which was originally developed to treat coronary flow obstruction, has also been proposed as an alternative to reduce the risk of thrombus formation. The aim of this study is to understand the impact of BASILICA on the valve-in-valve thrombogenicity using computational fluid dynamics simulations...
March 30, 2021: Journal of Biomechanics
https://read.qxmd.com/read/33517391/aortic-valve-neocuspidization-with-autologous-pericardium-in-adult-patients-uk-experience-and-meta-analytic-comparison-with-other-aortic-valve-substitutes
#19
REVIEW
Umberto Benedetto, Shubhra Sinha, Arnaldo Dimagli, Lauren Dixon, Serban Stoica, Lucia Cocomello, Cesare Quarto, Gianni D Angelini, Uday Dandekar, Massimo Caputo
OBJECTIVES: We sought to provide further evidence on the safety and efficacy of aortic valve neocuspidization (AVNeo) using autologous pericardium in adult patients with aortic valve disease by reporting clinical and echocardiographic results from the first UK experience and performing a meta-analytic comparison with other biological valve substitutes. METHODS: We reported clinical and echocardiographic outcomes of 55 patients (mean age 58 ± 15 years) undergoing AVNeo with autologous pericardium in 2 UK centres from 2018 to 2020...
July 14, 2021: European Journal of Cardio-thoracic Surgery
https://read.qxmd.com/read/33489295/numerical-models-for-assessing-the-risk-of-leaflet-thrombosis-post-transcatheter-aortic-valve-in-valve-implantation
#20
JOURNAL ARTICLE
Romina Plitman Mayo, Halit Yaakobovich, Ariel Finkelstein, Shawn C Shadden, Gil Marom
Leaflet thrombosis has been suggested as the reason for the reduced leaflet motion in cases of hypoattenuated leaflet thickening of bioprosthetic aortic valves. This work aimed to estimate the risk of leaflet thrombosis in two post-valve-in-valve (ViV) configurations, using five different numerical approaches. Realistic ViV configurations were calculated by modelling the deployments of the latest version of transcatheter aortic valve devices (Medtronic Evolut PRO, Edwards SAPIEN 3) in the surgical Sorin Mitroflow...
December 2020: Royal Society Open Science
keyword
keyword
50394
1
2
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.