Add like
Add dislike
Add to saved papers

Automated detection of steno-occlusive lesion on time-of-flight magnetic resonance angiography: an observer performance study.

BACKGROUND AND PURPOSE: Intracranial steno-occlusive lesions are responsible for acute ischemic stroke. However, the clinical benefits of artificial intelligence-based methods for detecting pathologic lesions in intracranial arteries have not been evaluated. We aimed to validate the clinical utility of an artificial intelligence model for detecting steno-occlusive lesions in the intracranial arteries.

MATERIALS AND METHODS: Overall, 138 TOF-MRA images were collected from two institutions, which served as internal (n = 62) and external (n = 76) test sets, respectively. Each study was reviewed by five radiologists (two neuroradiologists and three radiology residents) to compare the usage and non-usage of our proposed artificial intelligence model for TOF-MRA interpretation. They identified the steno-occlusive lesions and recorded their reading time. Observer performance was assessed using the area under the Jackknife free-response receiver operating characteristic curve and reading time for comparison.

RESULTS: The average area under the Jackknife free-response receiver operating characteristic curve for the five radiologists demonstrated an improvement from 0.70 without artificial intelligence to 0.76 with artificial intelligence ( P = .027). Notably, this improvement was most pronounced among the three radiology residents, whose performance metrics increased from 0.68 to 0.76 ( P = .002). Despite an increased reading time upon using artificial intelligence, there was no significant change among the readings by radiology residents. Moreover, the use of artificial intelligence resulted in improved inter-observer agreement among the reviewers (the intraclass correlation coefficient increased from 0.734 to 0.752).

CONCLUSIONS: Our proposed artificial intelligence model offers a supportive tool for radiologists, potentially enhancing the accuracy of detecting intracranial steno-occlusion lesions on TOF-MRA. Less-experienced readers may benefit the most from this model. ABBREVIATIONS: AI = Artificial intelligence; AUC = Area under the receiver operating characteristic curve; AUFROC = Area under the Jackknife free-response receiver operating characteristic curve; DL = Deep learning; ICC = Intraclass correlation coefficient; IRB = Institutional Review Boards; JAFROC = Jackknife free-response receiver operating characteristic.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app