Effect of Long-Acting Diquafosol Sodium on Astigmatism Measurement Repeatability in Preoperative Cataract Cases with Dry Eyes: A Multicenter Prospective Study.

INTRODUCTION: Dry eye can compromise corneal astigmatism measurement repeatability during preoperative cataract surgery examination. No previous studies have analyzed the effectiveness of long-acting 3% diquafosol sodium (LA-DQS) on astigmatism measurement repeatability. This research assessed the effect of LA-DQS on astigmatism measurement repeatability in preoperative patients with cataract and short tear break-up time (TBUT) type dry eyes in both eyes of the same patient. Correlations between repeatability and TBUT, corneal high-order aberrations (HOAs), and corneal astigmatism magnitude were also analyzed.

METHODS: In total, 122 eyes (61 patients) with short TBUT-type dry eye were enrolled. Preoperatively, only one eye of all patients was treated with LA-DQS for 4 weeks. TBUT and corneal HOAs were checked using CASIA 2 before and 4 weeks post-treatment. The cylindrical power and meridian of astigmatism were measured at 3- and 4-week post-treatment using IOLMaster 700. Power vectors J0 and J45 were used for astigmatism calculations. Repeatability of astigmatism measurements was assessed as the within-subject standard deviation (Sw). The relative effects of TBUT and HOAs on J0 Sw and J45 Sw were also analyzed. Comparative changes in these variables were evaluated between treated and non-treated eyes, with additional analysis of their correlations.

RESULTS: Treated eyes exhibited significant improvements in TBUT, HOAs, and post-treatment measurements of J0 Sw and J45 Sw at 3 and 4 weeks. In non-treated eyes, J0 Sw and J45 Sw showed significant correlation with TBUT and corneal HOAs. HOAs showed stronger relative associations with J0 Sw and J45 Sw than TBUT. In non-treated eyes, no significant correlation was found between cylindrical power and astigmatism measurement repeatability.

CONCLUSIONS: In short TBUT-type dry eye, preoperative treatment with LA-DQS significantly improved astigmatism measurement repeatability. This may improve the precision of intraocular lens (IOL) power calculations regardless of the magnitude of corneal astigmatism, especially when toric IOLs are used.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app