We have located links that may give you full text access.
Journal Article
Review
A literature review of biomechanical studies on physiological and pathological sacroiliac joints: Articular surface structure, joint motion, dysfunction and treatments.
Clinical Biomechanics 2024 March 22
BACKGROUND: Sacroiliac joints are affected by mechanical environments; the joints are formed under mechanical stimulation, receive impact of walking between the upper and lower parts of the bodies and can be a cause of pain due to non-physiological loads. However, there are so far very few studies that reviewed biomechanics of physiological and pathological sacroiliac joints. This review article aims to describe the current sacroiliac joint biomechanics.
METHODS: Previous original papers have been summarized based on three categories: articular surface structure, sacroiliac joint motion and sacroiliac joint dysfunction and treatments.
FINDINGS: Although the articular surface morphologies vary greatly from individual to individual, many researchers have tried to classify the joints into several types. It has been suggested that the surface morphologies may not change regardless of joint dysfunction, however, the relationship between the joint structure and pain are still unclear. The range of sacroiliac joint motion is demonstrated to be less than 1 mm and there is no difference between physiological and pathological joints. The sacroiliac joint absorbs shock within the pelvis by the joint structures of pelvic morphology, ligaments and fat tissues. The morphology and motion of the sacroiliac joints may be optimized for upright bipedal walking.
INTERPRETATION: There is no doubt that pelvic mechanical environments affect pain induction and treatment; however, no one has yet provided a concrete explanation. Future research could help develop treatments based on sacroiliac joint biomechanics to support joint function.
METHODS: Previous original papers have been summarized based on three categories: articular surface structure, sacroiliac joint motion and sacroiliac joint dysfunction and treatments.
FINDINGS: Although the articular surface morphologies vary greatly from individual to individual, many researchers have tried to classify the joints into several types. It has been suggested that the surface morphologies may not change regardless of joint dysfunction, however, the relationship between the joint structure and pain are still unclear. The range of sacroiliac joint motion is demonstrated to be less than 1 mm and there is no difference between physiological and pathological joints. The sacroiliac joint absorbs shock within the pelvis by the joint structures of pelvic morphology, ligaments and fat tissues. The morphology and motion of the sacroiliac joints may be optimized for upright bipedal walking.
INTERPRETATION: There is no doubt that pelvic mechanical environments affect pain induction and treatment; however, no one has yet provided a concrete explanation. Future research could help develop treatments based on sacroiliac joint biomechanics to support joint function.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app