False positive elevation in serum creatinine: a case report.
BACKGROUND: Paraproteins can interfere with several substances, producing erroneous laboratory measurements. The diagnosis of kidney disease in patients with hematological disorders has important prognosis implications. An elevated creatinine with no other signs of kidney disease should prompt the idea of a spurious creatinine. Communication between the clinical team and the laboratory is key.
CASE PRESENTATION: In this case, we present a 68-year-old woman with an elevated creatinine and an IgM lambda paraprotein. Interestingly, there were no other signs of chronic kidney disease besides the creatinine value, with no albuminuria or microhematuria. A kidney biopsy showed normal parenchyma and ruled out the possibility of paraprotein-related damage. The monoclonal component and creatinine levels raised parallelly during follow-up while maintaining normal urea levels. This prompted the hypothesis of a falsely elevated creatinine. It was confirmed with a normal glomerular filtration rate determined by a radioisotope, a cystatin C measurement and a reduction in creatinine when diluting the sample.
CONCLUSION: It is important to consider the possibility of a falsely elevated creatinine in patients with paraproteinemia and no other signs of kidney disease to avoid unnecessary diagnostic tests and for the prognostic implications.
CASE PRESENTATION: In this case, we present a 68-year-old woman with an elevated creatinine and an IgM lambda paraprotein. Interestingly, there were no other signs of chronic kidney disease besides the creatinine value, with no albuminuria or microhematuria. A kidney biopsy showed normal parenchyma and ruled out the possibility of paraprotein-related damage. The monoclonal component and creatinine levels raised parallelly during follow-up while maintaining normal urea levels. This prompted the hypothesis of a falsely elevated creatinine. It was confirmed with a normal glomerular filtration rate determined by a radioisotope, a cystatin C measurement and a reduction in creatinine when diluting the sample.
CONCLUSION: It is important to consider the possibility of a falsely elevated creatinine in patients with paraproteinemia and no other signs of kidney disease to avoid unnecessary diagnostic tests and for the prognostic implications.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app