Effect of Russian current expert modes on quadriceps muscle torque in healthy adults: A single-blinded randomized controlled trial.
PloS One 2024
BACKGROUND: Russian current (RC), a well-known neuromuscular electrical stimulation operating at 2500 Hz, has demonstrated significant strength improvement over traditional exercises due to its high tolerance and low pain provocation. Despite extensive NMES parameter research, the specific effects of expert modes, particularly ON2 and Rest, remain unexplored. This study investigates the direct effect of these expert modes on quadriceps muscle strength in healthy adults.
METHODS: This is a single-blind, randomization-controlled trial. Forty-eight healthy university students (31 females, 17 males) were assigned in two randomized experimental groups either the ON2 or Rest mode for a 15-minute electrical stimulation session. Quadriceps maximum voluntary isokinetic contraction measurements were taken before and directly after RC application using Biodex Medical Systems 4 pro isokinetic dynamometer.
RESULTS: Both RC modes significantly increased the quadriceps muscle torque in healthy adults compared to baseline (p<0.05). Baseline mean torque was 123.28 (SD = 38.8), and post- RC mean torque was 136.67 (SD = 45.76). Deviation from normality was observed at baseline (p = 0.034) and persisted post-RC application (p = 0.017). The Wilcoxon test reported significant increases in quadriceps muscle knee torque for both ON2 and Rest groups (p < 0.001). The lack of ties in ranks and negative Z-values highlight the robustness of the observed effects.
CONCLUSION: The findings of this study align with previous research on NMES and RC supporting the idea that electrical stimulation enhances muscle strength, selecting the appropriate RC expert modes can assist physiotherapist in tailoring rehabilitation program to achieve their specific strength goals.
METHODS: This is a single-blind, randomization-controlled trial. Forty-eight healthy university students (31 females, 17 males) were assigned in two randomized experimental groups either the ON2 or Rest mode for a 15-minute electrical stimulation session. Quadriceps maximum voluntary isokinetic contraction measurements were taken before and directly after RC application using Biodex Medical Systems 4 pro isokinetic dynamometer.
RESULTS: Both RC modes significantly increased the quadriceps muscle torque in healthy adults compared to baseline (p<0.05). Baseline mean torque was 123.28 (SD = 38.8), and post- RC mean torque was 136.67 (SD = 45.76). Deviation from normality was observed at baseline (p = 0.034) and persisted post-RC application (p = 0.017). The Wilcoxon test reported significant increases in quadriceps muscle knee torque for both ON2 and Rest groups (p < 0.001). The lack of ties in ranks and negative Z-values highlight the robustness of the observed effects.
CONCLUSION: The findings of this study align with previous research on NMES and RC supporting the idea that electrical stimulation enhances muscle strength, selecting the appropriate RC expert modes can assist physiotherapist in tailoring rehabilitation program to achieve their specific strength goals.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app