We have located links that may give you full text access.
Evaluation of a custom designed hybridisation assay for whole genome sequencing of human adenoviruses direct from clinical samples.
Journal of Clinical Virology 2024 January 12
BACKGROUND: Human Adenoviruses are a common cause of disease and can cause significant morbidity and mortality in immunocompromised patients. Nosocomial transmission events can occur with whole genome sequencing playing a crucial role. This study evaluates the performance of a custom designed SureSelectXT target enrichment assay based on 14 adenovirus genomes for sequencing direct from clinical samples.
METHODS: Modifications were made to the SureSelectXT low input protocol to enhance performance for viral targets. Consensus sequences were generated using an in-house designed three stage bioinformatics pipeline. We assessed, percentage of on target reads, average depth of coverage and percentage genome coverage to determine assay performance across a range of sample matrices.
RESULTS: Whole genome sequences were successfully generated for 91.6 % of samples assessed. Adenovirus DNA concentration was a good indicator of enrichment success. Highly specific enrichment was observed with only 6 % of samples showing < 50 % on target reads. Respiratory and faecal samples performed well where bloods showed higher levels of non-specific enrichment likely confounded by low adenovirus DNA concentrations. Protocol performance did not appear impacted by Adenovirus type or species.
CONCLUSION: Overall performance of this modified SureSelectXT protocol appears in line with previously published works although there are some confounding factors requiring further investigation. The use of a small RNA bait set has the potential to reduce associated costs which can be prohibitive.
METHODS: Modifications were made to the SureSelectXT low input protocol to enhance performance for viral targets. Consensus sequences were generated using an in-house designed three stage bioinformatics pipeline. We assessed, percentage of on target reads, average depth of coverage and percentage genome coverage to determine assay performance across a range of sample matrices.
RESULTS: Whole genome sequences were successfully generated for 91.6 % of samples assessed. Adenovirus DNA concentration was a good indicator of enrichment success. Highly specific enrichment was observed with only 6 % of samples showing < 50 % on target reads. Respiratory and faecal samples performed well where bloods showed higher levels of non-specific enrichment likely confounded by low adenovirus DNA concentrations. Protocol performance did not appear impacted by Adenovirus type or species.
CONCLUSION: Overall performance of this modified SureSelectXT protocol appears in line with previously published works although there are some confounding factors requiring further investigation. The use of a small RNA bait set has the potential to reduce associated costs which can be prohibitive.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app