Long-term experience of the modified David V re-implantation technique for valve-sparing aortic root replacement.

OBJECTIVE: The modified David V technique is one of the valve-sparing aortic root replacement (V-SARR) techniques, which is an alternative to traditional composite valve graft root replacement techniques. We aimed to analyse our long-term experience with the modified David V re-implantation technique for the treatment of aortic root aneurysm and significant aortic valve insufficiency.

METHODS: From March 2009 to November 2021 the modified David V re-implantation technique, one of the V-SARR techniques, was performed on 48 patients in our centre. The results were analysed retrospectively. Two different-sized grafts were used in all patients. The grafts used in the proximal position were larger than the distal grafts. We performed both intra-operative and post-procedural transoesophageal echocardiography on each patient. All patients were followed by means of transthoracic echocardiography. The mean follow-up period was 5.7 ± 3.1 years.

RESULTS: The mean age of this cohort was 56.3 ± 14.3 years (24-79) and the majority were men (75%). The mean aortic root diameter was 5.1 ± 0.6 cm. The mean diameter for the assending aorta was 5.4 ± 2.1 cm. The in-hospital mortality rate was 4.2% ( n = 2). One patient needed aortic valve replacement in the early postoperative period. Two (4.2%) patients died in the early postoperative period and four (8.3%) died in the late postoperative period. Overall survival was 91 ± 4 and 86 ± 5% at one and five years, respectively. Aortic valve insufficiency was at moderate levels postoperatively. Freedom from moderate to severe residual aortic insufficiency was 89.6% at 10 years. None of the patients needed late re-operation of the aortic valve postoperatively. Freedom from valve re-operation was 100% at the end of the follow up.

CONCLUSION: Our study shows that the David V technique is associated with excellent long-term durability, a remarkably low rate of valve-related complications, and it protects the re-implanted native aortic valve from a second operation. Additionally this technique could be safely implemented in patients with a bicuspid aortic valve and acute type A aortic dissection without leaflet deformity.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app