Add like
Add dislike
Add to saved papers

Optimal Protocol and Clinical Usefulness of 123 I-MIBG Cardiac Scintigraphy for Differentiation of Parkinson's Disease and Dementia with Lewy Body from Non-Parkinson's Diseases.

PURPOSE: 123 I-metaiodobenzylguanidine (MIBG) cardiac scintigraphy was a useful imaging modality for the diagnosis of Parkinson's disease, but its diagnostic performances were variably reported. This retrospective study compared the diagnostic performances and investigated the optimal imaging protocol of 123 I-MIBG cardiac scintigraphy at various imaging time points in patients suspected of Parkinson's disease in clinical practice.

METHODS: In patients suspected of Parkinson's disease, clinical records, autonomic function tests, and 123 I-MIBG cardiac scintigraphy were retrospectively reviewed. Semi-quantitative parameters such as heart-to-mediastinum ratio (HMR) and washout rate (WR) were calculated and compared at 15 min, 1 h, 2 h, 3 h, and 4 h post-injection (p.i.). of 123 I-MIBG cardiac scintigraphy. Group A consisted of Parkinson's disease (PD), Parkinson's disease dementia (PDD), and dementia with Lewy body (DLB), and group B consisted of non-Parkinson's diseases such as multiple system atrophy (MSA), progressive supranuclear palsy (PSP), drug-induced parkinsonism (DIP), essential tremor (ET), Parkinson-plus syndrome (PPS), and unspecified secondary parkinsonism (NA). The diagnostic performances of HMR and WR were compared for differentiation of group A from group B, and their clinical usefulness and optimal imaging time points were explored.

RESULTS: Seventy-eight patients were included in group A (67 PD, 7 PDD, 4 DLB), and 18 patients were included in group B (5 MSA, 3 PSP, 2 DIP, 2 ET, 1 PPS, and 1 NA). Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value of HMR and WR were maximized at 4 h p.i., (82.1%, 85.7%, 82.6%, 97.0%, and 46.2%; cutoff threshold < 1.717; area under curve 0.8086) and at the time interval between 1 and 4 h p.i. (65.4%, 85.7%, 68.5%, 96.2%, and 30.8%; cutoff threshold > 24.1%; area under curve 0.8246), respectively, and PPVs of both HMR and WR persistently showed greater than 92.7% at earlier time points and shorter time intervals.

CONCLUSION: This study reassured that 4-h-delayed imaging is recommended for the best diagnostic performances in 123 I-MIBG cardiac scintigraphy. Although it showed suboptimal diagnostic performances to differentiate PD, PDD, and DLB from non-Parkinson's diseases, it can be useful as an auxiliary measure for the differential diagnosis in usual clinical practice.

SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13139-023-00790-w.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app