Meta-analysis assessing the sensitivity and specificity of 18 F-FDG PET/CT for the diagnosis of prosthetic valve endocarditis (PVE) using individual patient data (IPD).

IMPORTANCE: The use of 18 F-FDG PET/CT in diagnostic algorithms for PVE has increased since publication of studies and guidelines advocating its use. The assessment of test accuracy has been limited by small study sizes. We undertook a systematic review using individual patient data (IPD) meta-analysis techniques.

OBJECTIVE: To estimate the summary sensitivity and specificity of 18 F-FDG PET/CT in diagnosing PVE. We also assessed the effect of patient factors on test accuracy as defined by changes in the Odds Ratios associated with each factor. The effect of the PET/CT study on the final diagnosis was also assessed when compared to the preliminary Duke classification to determine in which patient group 18 F-FDG PET/CT had the greatest utility.

STUDY SELECTION: Studies were included if PET/CT was performed for suspicion of PVE and IPD of both the PET/CT result and final diagnosis defined by a gold-standard assessment was available. There were three possible final diagnoses ("definite PVE", "possible PVE" and "rejected PVE").

RESULTS: Seventeen studies were included with IPD available for 537 patients (from 538 scans). The summary sensitivity and specificity were 85.0 % (95% CI 74.2 - 91.8 %) and 86.5 % (95% CI 75.8 - 92.9%) respectively when patients with final diagnosis of "possible PVE" were classified as positive for PVE. When this group was classified as negative for PVE, sensitivity was 87.4% (95% CI 80.4 - 92.1%) and specificity was 84.9% (95% CI 71.5 - 92.6%). Patients with a known pathogen (especially coagulase negative staphylococcal species), elevated CRP, a biological or aortic valve infection appeared more likely to have an accurate PET/CT diagnosis. Those with a mechanical valve, prior antibiotic treatment or a TAVR valve were less likely to have an accurate test. Time since valve implantation and the presence of surgical adhesive did not appear to affect test accuracy. Of the patients with a preliminary Duke classification of "possible PVE", 84 % received a more conclusive final diagnosis of "definite" or "rejected" PVE after the PET/CT study.

CONCLUSIONS AND RELEVANCE: 18 F-FDG PET/CT has high sensitivity and specificity in diagnosing PVE and the diagnostic utility is greatest in patients with a preliminary Duke classification of "possible PVE". Some patient factors appear to affect test accuracy, though these results should be interpreted with caution given low patient numbers for subgroup analyses.

Full text links

For the best experience, use the Read mobile app

Group 7SearchHeart failure treatmentPapersTopicsCollectionsEffects of Sodium-Glucose Cotransporter 2 Inhibitors for the Treatment of Patients With Heart Failure Importance: Only 1 class of glucose-lowering agents-sodium-glucose cotransporter 2 (SGLT2) inhibitors-has been reported to decrease the risk of cardiovascular events primarily by reducingSeptember 1, 2017: JAMA CardiologyAssociations of albuminuria in patients with chronic heart failure: findings in the ALiskiren Observation of heart Failure Treatment study.CONCLUSIONS: Increased UACR is common in patients with heart failure, including non-diabetics. Urinary albumin creatininineJul, 2011: European Journal of Heart FailureRandomized Controlled TrialEffects of Liraglutide on Clinical Stability Among Patients With Advanced Heart Failure and Reduced Ejection Fraction: A Randomized Clinical Trial.Review

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app