Journal Article
Meta-Analysis
Systematic Review
Add like
Add dislike
Add to saved papers

Diagnostic test accuracies of F-18 FDG PET for characterisation of cardiac masses compared to conventional imaging techniques: systematic review and meta-analysis.

OBJECTIVE: The present systematic review and meta-analysis compared the diagnostic performance of F-18 fludeoxyglucose positron emission tomography (18 F-FDG PET) and conventional imaging, including MRI, echocardiography, and CT, in characterising cardiac masses.

METHODS: A literature search of the PubMed, Cochrane, and EMBASE databases for studies comparing the diagnostic accuracies of 18 F-FDG PET and conventional imaging in characterising cardiac masses, from inception of indexing to 31 July 2020, was performed. The Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality. Sensitivity and specificity across the studies were determined, positive and negative likelihood ratios (LR+ and LR-, respectively) were calculated, and summary receiver operating characteristic curves were constructed.

RESULTS: Of six included studies ( n = 212 patients), 18 F-FDG PET demonstrated a pooled sensitivity of 0.89 (95% confidence interval [CI] 0.81-0.94) and a pooled specificity of 0.89 (95% CI 0.80-0.94). LR syntheses yielded an overall LR+ of 7.9 (95% CI 4.3-14.6) and LR- of 0.12 (95% CI 0.07-0.22). The calculated pooled diagnostic odds ratio (DOR) was 64 (95% CI 23-181). For conventional imaging, the pooled sensitivity was 0.70 (95% CI 0.57-0.81) and the pooled specificity was 0.96 (95% CI 0.88-0.98). LR syntheses yielded an overall LR+ of 16.1 (95% CI 5.8-44.5) and LR- of 0.31 (95% CI 0.21-0.46). The evaluated pooled DOR was 52 (95% CI 17-155).

CONCLUSION: 18 F-FDG PET and conventional imaging demonstrated comparable diagnostic accuracies for the characterisation of cardiac masses. Further large multicentre studies are, however, required to corroborate the diagnostic performances of 18 F-FDG PET and conventional imaging for the characterisation of cardiac masses.

ADVANCES IN KNOWLEDGE: No previous studies have comprehensively analysed the diagnostic performance of 18 F-FDG PET/CT compared with conventional imaging techniques including echocardiography, CT, and MRI. According to the current study, 18 F-FDG PET/CT yielded a pooled DOR of 64, whereas other conventional imaging techniques demonstrated a DOR of 52. As such, 18 F-FDG PET/CT demonstrated sensitivity and specificity, with a high pooled DOR comparable with other conventional imaging modalities.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app