We have located links that may give you full text access.
Technical Feasibility of Electromagnetic US/CT Fusion Imaging and Virtual Navigation in the Guidance of Spine Biopsies.
Ultraschall in der Medizin 2020 August 13
PURPOSE: To test the technical feasibility of electromagnetic computed tomography (CT) + ultrasound fusion (US)-guided bone biopsy of spinal lesions.
MATERIALS AND METHODS: This retrospective study included 14 patients referred for biopsy of spinal bone lesions without cortical disruption or intervertebral disc infection. Lesions were located in the sacrum (n = 4), lumbar vertebral body (n = 7) or intervertebral disc (n = 3). Fusion technology matched a pre-procedure CT scan with real-time ultrasound. The first six procedures were performed under both standard CT and CT + US fusion guidance (group 1). In the last eight procedures, the needle was positioned under fusion imaging guidance alone, and CT was only used at the end of needle placement to confirm correct positioning (group 2). Additionally, we retrieved 8 patients (controls) with location-matched lesions as group 2, which were biopsied in the past with the standard CT-guided technique. The procedure duration and number of CT passes were recorded.
RESULTS: Mean procedure duration and median CT pass number were significantly higher in group 1 vs. group 2 (45 ± 5 vs. 26 ± 3 minutes, p = 0.002 and 7; 5.25-8.75 vs. 3; 3-3.25, p = 0.001). In controls, the mean procedure duration was 47 ± 4 minutes (p = 0.001 vs. group 2; p = 0.696 vs. group 1) and the number of CT passes was 6.5 (5-8) (p = 0.001 vs. group 2; p = 0.427 vs. group 1). No complications occurred and all specimens were adequate overall. In one case in group 2, the needle position was modified according to CT assessment before specimen withdrawal.
CONCLUSION: Electromagnetic CT+US fusion-guided bone biopsy of spinal lesions is feasible and safe. Compared to conventional CT guidance, it may reduce procedural time and the number of CT passes.
MATERIALS AND METHODS: This retrospective study included 14 patients referred for biopsy of spinal bone lesions without cortical disruption or intervertebral disc infection. Lesions were located in the sacrum (n = 4), lumbar vertebral body (n = 7) or intervertebral disc (n = 3). Fusion technology matched a pre-procedure CT scan with real-time ultrasound. The first six procedures were performed under both standard CT and CT + US fusion guidance (group 1). In the last eight procedures, the needle was positioned under fusion imaging guidance alone, and CT was only used at the end of needle placement to confirm correct positioning (group 2). Additionally, we retrieved 8 patients (controls) with location-matched lesions as group 2, which were biopsied in the past with the standard CT-guided technique. The procedure duration and number of CT passes were recorded.
RESULTS: Mean procedure duration and median CT pass number were significantly higher in group 1 vs. group 2 (45 ± 5 vs. 26 ± 3 minutes, p = 0.002 and 7; 5.25-8.75 vs. 3; 3-3.25, p = 0.001). In controls, the mean procedure duration was 47 ± 4 minutes (p = 0.001 vs. group 2; p = 0.696 vs. group 1) and the number of CT passes was 6.5 (5-8) (p = 0.001 vs. group 2; p = 0.427 vs. group 1). No complications occurred and all specimens were adequate overall. In one case in group 2, the needle position was modified according to CT assessment before specimen withdrawal.
CONCLUSION: Electromagnetic CT+US fusion-guided bone biopsy of spinal lesions is feasible and safe. Compared to conventional CT guidance, it may reduce procedural time and the number of CT passes.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app