Cyclic testing of tibialis tendon allografts for anterior cruciate ligament reconstruction using suture-post versus spiked washer tibial fixation.
Clinical Biomechanics 2019 July 24
BACKGROUND: The purpose of this study was to directly compare spiked washer and suture-post tibial-sided fixation techniques used for anterior cruciate ligament reconstruction by measuring anterior tibial translation during cyclic tests.
METHODS: Fresh-frozen human knees were tested using a robotic system that applied 250 cycles of anterior-posterior tibial force (134 N) at 30° flexion, while recording tibial translation. Ten intact knees were tested to collect baseline data for native specimens. A single knee was selected to test ligament reconstructions using doubled tibialis tendon allografts. All grafts were fixed proximally using an EndoButton™, and the tibial end of the graft was fixed with either a spiked washer or with a suture post placed at two different locations (near and distant) relative to the tibial tunnel.
FINDINGS: Mean first cycle translation for intact knees was 4.8 (sd 1.8) mm; means after reconstruction were 2.6 (sd 0.9) mm (spiked washer), 10.1 (sd 1.9) mm (suture post near), and 10.4 (sd 1.5) mm (suture post distant). Corresponding means for translation increase over 250 cycles were 0.3 (sd 0.2) mm, 3.6 (sd 1.3) mm, 7.2 mm (sd 0.9) mm, and 8.0 (sd 1.3) mm. All mean increases (first cycle and cyclic) after ACL reconstruction were significantly greater than those for the intact knees, and all means with a suture post were significantly greater than those with a spiked washer. There were no significant differences between mean translations for near and distant suture post locations.
INTERPRETATION: Use of suture post fixation for anterior cruciate ligament reconstruction is questioned since increases in anterior tibial translation could lead to excessive post-operative knee laxity and possibly early clinical failure.
METHODS: Fresh-frozen human knees were tested using a robotic system that applied 250 cycles of anterior-posterior tibial force (134 N) at 30° flexion, while recording tibial translation. Ten intact knees were tested to collect baseline data for native specimens. A single knee was selected to test ligament reconstructions using doubled tibialis tendon allografts. All grafts were fixed proximally using an EndoButton™, and the tibial end of the graft was fixed with either a spiked washer or with a suture post placed at two different locations (near and distant) relative to the tibial tunnel.
FINDINGS: Mean first cycle translation for intact knees was 4.8 (sd 1.8) mm; means after reconstruction were 2.6 (sd 0.9) mm (spiked washer), 10.1 (sd 1.9) mm (suture post near), and 10.4 (sd 1.5) mm (suture post distant). Corresponding means for translation increase over 250 cycles were 0.3 (sd 0.2) mm, 3.6 (sd 1.3) mm, 7.2 mm (sd 0.9) mm, and 8.0 (sd 1.3) mm. All mean increases (first cycle and cyclic) after ACL reconstruction were significantly greater than those for the intact knees, and all means with a suture post were significantly greater than those with a spiked washer. There were no significant differences between mean translations for near and distant suture post locations.
INTERPRETATION: Use of suture post fixation for anterior cruciate ligament reconstruction is questioned since increases in anterior tibial translation could lead to excessive post-operative knee laxity and possibly early clinical failure.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app