We have located links that may give you full text access.
Ultrasound Predicts White Matter Integrity after Hypothermia Therapy in Neonatal Hypoxic-Ischemic Injury.
BACKGROUND: Hypoxic-ischemic injury (HII) is a major cause of neonatal death and neurodevelopmental disability. Head ultrasounds (HUS) in neonates with HII often show enhanced gray/white matter differentiation. We assessed the significance of this finding in predicting white matter structural integrity measured by diffusion tensor imaging (DTI) in neonates with HII.
METHODS: We performed a quantitative region of interest-based analysis of white and gray matter echogenicity within the cingulate gyrus on pre- and posthypothermia HUS. We also completed a quantitative analysis of fractional anisotropy (FA) and mean (MD), axial (AD), and radial (RD) diffusivity within the bilateral anterior and posterior centrum semiovale (CSO) on posthypothermia brain magnetic resonance imaging. For HUS studies, we calculated a white-to-gray matter echogenicity ratio (WGR) and subsequently correlated it to DTI measurements.
RESULTS: Forty-two term neonates with HII who underwent hypothermia therapy were included. Significant correlation was found between prehypothermia WGR and MD, AD, and RD values in the left anterior CSO (r = .38-.40, P = .02). Prehypothermia WGR also correlated with the following: MD and RD in the right anterior CSO (r = .35-.36, P = .04), MD and AD in the right posterior CSO (r = .32-.45, P = .008-.03), and AD in the left posterior CSO (r = .47, P = .005). No significant correlation was found either between prehypothermia WGR and FA values in the bilateral anterior and posterior CSO or between posthypothermia WGR and all DTI scalars in the bilateral anterior and posterior CSO.
CONCLUSIONS: Prehypothermia HUS WGR may predict posthypothermia white matter structural integrity and is potentially an early and easily obtainable biomarker of severity in neonatal HII.
METHODS: We performed a quantitative region of interest-based analysis of white and gray matter echogenicity within the cingulate gyrus on pre- and posthypothermia HUS. We also completed a quantitative analysis of fractional anisotropy (FA) and mean (MD), axial (AD), and radial (RD) diffusivity within the bilateral anterior and posterior centrum semiovale (CSO) on posthypothermia brain magnetic resonance imaging. For HUS studies, we calculated a white-to-gray matter echogenicity ratio (WGR) and subsequently correlated it to DTI measurements.
RESULTS: Forty-two term neonates with HII who underwent hypothermia therapy were included. Significant correlation was found between prehypothermia WGR and MD, AD, and RD values in the left anterior CSO (r = .38-.40, P = .02). Prehypothermia WGR also correlated with the following: MD and RD in the right anterior CSO (r = .35-.36, P = .04), MD and AD in the right posterior CSO (r = .32-.45, P = .008-.03), and AD in the left posterior CSO (r = .47, P = .005). No significant correlation was found either between prehypothermia WGR and FA values in the bilateral anterior and posterior CSO or between posthypothermia WGR and all DTI scalars in the bilateral anterior and posterior CSO.
CONCLUSIONS: Prehypothermia HUS WGR may predict posthypothermia white matter structural integrity and is potentially an early and easily obtainable biomarker of severity in neonatal HII.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app