Add like
Add dislike
Add to saved papers

Modeling of Microbubble-Enhanced High-Intensity Focused Ultrasound.

Heat enhancement at the target in a high intensity focused ultrasound (HIFU) field is investigated by considering the effects of the injection of microbubbles in the vicinity of the tumor to be ablated. The interaction between the bubble cloud and the HIFU field is investigated using a 3-D numerical model. The propagation of non-linear ultrasonic waves in the tissue or in a phantom medium is modeled using the compressible Navier-Stokes equations on a fixed Eulerian grid, while the microbubbles dynamics and motion are modeled as discrete singularities, which are tracked in a Lagrangian framework. These two models are coupled to each other such that both the acoustic field and the bubbles influence each other. The resulting temperature rise in the field is calculated by solving a heat transfer equation applied over a much longer time scale. The compressible continuum part of the model is validated by conducting axisymmetric HIFU simulations without microbubbles and comparing the pressure and temperature fields against available experiments. The coupled Eulerian-Lagrangian approach is then validated against existing experiments conducted with a phantom tissue. The bubbles are distributed randomly in a 3-D fashion inside a cylindrical volume, while the background acoustic field is assumed axisymmetric. The presence of microbubbles modifies the ultrasound field in the focal region and significantly enhances heat deposition. The various mechanisms through which heat deposition is increased are then examined. Among these effects, viscous damping of the bubble oscillations is found to be the main contributor to the enhanced heat deposition. The effects of the initial void fraction in the cloud are then sought by considering the changes in the attenuation of the primary ultrasonic wave and the modifications of the enhanced heat deposition in the focal region. It is observed that although high bubble void fractions lead to increased heat deposition, they also cause significant pre-focal heating because of acoustic shielding. The effects of the microbubble cloud size and its location in the focal region are studied, and the effects of these parameters in altering the temperature rise and the location of the temperature peak are discussed. It is found that concentrating the bubbles adjacent to the focus and farther away from the acoustic source leads to effective heat deposition. Finally, the presence of a shell at the bubble surface, as in contrast agents, is seen to reduce heat deposition by restraining bubble oscillations.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app