We have located links that may give you full text access.
Case Reports
Journal Article
Recurrent Exposure of XEN Gel Stent Implant and Conjunctival Erosion.
Journal of Glaucoma 2019 March
PURPOSE: The purpose of this study was to report a case of recurrent conjunctival erosion and XEN Gel Stent exposure after implantation in a primary open-angle glaucoma patient. Minimally invasive glaucoma surgery (MIGS) is a new approach in glaucoma surgery, and there is a lack of published data with regard to the management of postoperative ocular surface complications.
METHODS: This is a case report of a patient with a persistent corneal erosion after XEN Gel Stent implantation. A standalone MIGS surgery was planned for both eyes in this case of refractory glaucoma. Despite a first surgical revision, the patient was suffering from a chronic leaking bleb, an exposed XEN Gel Stent, and severe hypotonia in the left eye.
RESULTS: A free conjunctival autografting technique covered with a complementary amniotic membrane graft was performed under local anesthesia. One month following bleb revision, the intraocular pressure was 13 mm Hg on medical treatment, and slit-lamp examination showed a well-formed moderate bleb with no leakage.
CONCLUSIONS: This is the first described case of the use of a free conjunctival autograft to treat a persistently leaking bleb after XEN Gel Stent implantation. This case highlights the potential complication of conjunctival erosion due to XEN Gel Stent implantation. It emphasizes the management of complicated filtration blebs after MIGS surgery.
METHODS: This is a case report of a patient with a persistent corneal erosion after XEN Gel Stent implantation. A standalone MIGS surgery was planned for both eyes in this case of refractory glaucoma. Despite a first surgical revision, the patient was suffering from a chronic leaking bleb, an exposed XEN Gel Stent, and severe hypotonia in the left eye.
RESULTS: A free conjunctival autografting technique covered with a complementary amniotic membrane graft was performed under local anesthesia. One month following bleb revision, the intraocular pressure was 13 mm Hg on medical treatment, and slit-lamp examination showed a well-formed moderate bleb with no leakage.
CONCLUSIONS: This is the first described case of the use of a free conjunctival autograft to treat a persistently leaking bleb after XEN Gel Stent implantation. This case highlights the potential complication of conjunctival erosion due to XEN Gel Stent implantation. It emphasizes the management of complicated filtration blebs after MIGS surgery.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app