Add like
Add dislike
Add to saved papers

The Correction of Systematic Error due to Plaster and Fiberglass Casts on HR-pQCT Bone Parameters Measured In Vivo at the Distal Radius.

Due to difficulty assessing healing of distal radius fractures using conventional radiography, there is interest in using high resolution peripheral quantitative computed tomography (HR-pQCT) to track healing at the microarchitectural level. Unfortunately, the plaster-of-Paris and fiberglass casts used to immobilize fractures affect HR-pQCT measurements due to beam hardening, and increased noise. The challenge is compounded because casts have variable thickness, and an individual patient will often have their cast changed 2-3 times during the course of treatment. This study quantifies the effect of casts within a clinically relevant range of thicknesses on measured bone parameters at the distal radius, and establishes conversion equations to correct for systematic error in due to cast presence. Eighteen nonfractured participants were scanned by HR-pQCT in three conditions: no cast, plaster-of-Paris cast, and fiberglass cast. Measured parameters were compared between the baseline scan (no cast) and each cast scan to evaluate if systematic error exists due to cast presence. A linear regression model was used to determine an appropriate conversion for parameters that were found to have systematic error. Plaster-of-Paris casts had a greater range of thicknesses (3.2-9.5 mm) than the fiberglass casts (3.0-5.4 mm), and induced a greater magnitude of systematic error overall. Key parameters of interest were bone mineral density (total, cortical, and trabecular) and trabecular bone volume fraction, all of which were found to have systematic error due to presence of either cast type. Linear correlations between baseline and cast scans for these parameters were excellent (R2 > 0.98), and appropriate conversions could be determined within a margin of error less than a ±6% for the plaster-of-Paris cast, and ±4% for the fiberglass cast. We have demonstrated the effects of cast presence on bone microarchitecture measurements, and presented a method to correct for systematic error, in support of future use of HR-pQCT to study fracture healing.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app