JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
Optimization of Split-Bolus CT Urography: Effect of Differences in Allocation of Contrast Medium and Prolongation of Imaging Delay.
AJR. American Journal of Roentgenology 2017 July
OBJECTIVE: The purpose of this study was to find the optimal allocation ratio of contrast medium (CM) in split-bolus CT urography (CTU) and to investigate the effect of increased imaging delays for synchronous nephrographic-excretory phase imaging.
SUBJECTS AND METHODS: One hundred ninety-two patients were randomly assigned to one of three protocols with different allocation ratios of CM: group A, 30% of CM at first bolus and 70% of CM at second bolus; group B, 70% and 30%; or group C, 50% and 50%. Saline (250 mL) was administered after the first CM bolus. Patients were subdivided by different imaging delay times (8, 10, 12, and 14 minutes). The attenuation values of the renal cortex and medulla were measured, and the opacification and maximal caliber of each segment of the ureter were evaluated.
RESULTS: Renal cortical enhancement was significantly higher in group A (mean ± SD, 145.9 ± 17.5 HU) than group B (120.6 ± 106.3 HU). No significant difference in renal parenchymal enhancement was found with increased imaging delay times. The opacification and maximal caliber of each ureter segment showed no significant difference with different allocation ratios of CM or increased imaging delay times.
CONCLUSION: A split-bolus CTU protocol with a larger CM volume administered at the second injection and an 8-minute imaging delay was the optimal protocol with regard to opacification of the ureter, renal parenchymal enhancement, and shorter examination time.
SUBJECTS AND METHODS: One hundred ninety-two patients were randomly assigned to one of three protocols with different allocation ratios of CM: group A, 30% of CM at first bolus and 70% of CM at second bolus; group B, 70% and 30%; or group C, 50% and 50%. Saline (250 mL) was administered after the first CM bolus. Patients were subdivided by different imaging delay times (8, 10, 12, and 14 minutes). The attenuation values of the renal cortex and medulla were measured, and the opacification and maximal caliber of each segment of the ureter were evaluated.
RESULTS: Renal cortical enhancement was significantly higher in group A (mean ± SD, 145.9 ± 17.5 HU) than group B (120.6 ± 106.3 HU). No significant difference in renal parenchymal enhancement was found with increased imaging delay times. The opacification and maximal caliber of each ureter segment showed no significant difference with different allocation ratios of CM or increased imaging delay times.
CONCLUSION: A split-bolus CTU protocol with a larger CM volume administered at the second injection and an 8-minute imaging delay was the optimal protocol with regard to opacification of the ureter, renal parenchymal enhancement, and shorter examination time.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
Read by QxMD is copyright © 2021 QxMD Software Inc. All rights reserved. By using this service, you agree to our terms of use and privacy policy.
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app