Safe Cytotoxic Drug Preparation Using Closed-system Transfer Device: Technical and Practical Evaluation of a New Device (Vialshield/Texium) Comparatively to a Reference One (Phaseal).

Closed-system transfer devices enhance the drug handlers' protection against hazardous drugs exposure by prohibiting the escape of liquid or vapor from the system. PhaSeal (Becton Dickinson), a reference closed-system transfer device, includes a vial protector with an expansion chamber, and an injector with an enclosed needle. VialShield (CareFusion) is another more recent closed-system transfer device including an expansion-chamber and a non-return valve, designed to be used in association with Texium (CareFusion), a closed, needle-free male luer with its preassembled syringe. Evaluation of VialShield/Texium was done comparatively to a classic spike device (Spike Swan, Codan) and PhaSeal. Evaluation methods consisted in practical evaluation by pharmacy technicians (evaluation of ease to use by nine operators in practical conditions during a complete week of production), microbiological safety performance (by Media Fill Test), and leakage assessment (fluorescein, titanium tetrachloride smoke, and radioactive tracer). Results showed that 100% of those operators evaluated would be ready to use VialShield/Texium for daily use, whereas only 75% of them would be ready to use PhaSeal. The use of PhaSeal and VialShield/Texium increased the duration of preparations compared to Spike Swan. No microbiological growth was observed with any of the three devices. A leakage of smoke was observed only with Spike Swan. Fluorescein leakage assessment confirmed that PhaSeal is a performing closed system with a dry connection. Spike Swan showed fluorescein leaks. Fluorescein drops were visible on the connection sites of the VialShield/Texium. Nevertheless, no fluorescein was found on compress after connections swapping. Transfer performance, assessed using technetium-99m, was 98.1 ± 1.4%, 97.9 ± 1.1% and 97.0 ± 1.3% and dead volume of the devices, were 1.0 ± 0.8%, 1.7 ± 0.6%, and 3.0 ± 1.1% for Spike Swan, PhaSeal, and VialShield/Texium, respectively. VialShield/Texium appeared as a very interesting device with performances close to PhaSeal (except dry connection), with a higher satisfaction assessment from the operators.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app