Influences of fit and fill following hip arthroplasty using a cementless short-stem prosthesis.
Archives of Orthopaedic and Trauma Surgery 2015 November
INTRODUCTION: The purpose of this study consisted in examining the effects of fit and fill ratio of the Metha prosthesis (BBraun, Aesculap, Tuttlingen, Germany) on radiological and clinical outcomes at a follow-up of 1 year.
METHODS: 40 patients were included. Fit and fill ratio measurements, radiological and clinical examinations were performed preoperatively and postoperatively. Correlations were established between fit and fill ratio, and potential factors like sex, age, body mass index, Harris Hip Score and changes of radiological signs.
RESULTS: The whole cohort (100%) had a tight fit and fill ratio (>0.8) at the proximal level and at each follow-up. "Champagne-flute" configuration provoked high distal tight-fit and fill ratio. Poor distal fit and fill ratio compared to the proximal and the mid-stem level was measurable at each follow-up (p < 0.05). Correlations between fit and fill ratio and preoperative femur configurations were detectable.
CONCLUSIONS: Implanting the Metha prosthesis induces tight fit and fill ratio at the proximal and coated sections. Preoperative femur configuration should be considered to achieve best fit and fill situation and therefore excellent primary stability. In most cases "normal" and "stove-pipe" configurations provide good proximal fit and fill. Since "champagne-flute" configuration induces undesirable tight distal fit and fill ratio the size of the Metha (®) stem should be adequately increased to achieve a more proximal load transmission.
METHODS: 40 patients were included. Fit and fill ratio measurements, radiological and clinical examinations were performed preoperatively and postoperatively. Correlations were established between fit and fill ratio, and potential factors like sex, age, body mass index, Harris Hip Score and changes of radiological signs.
RESULTS: The whole cohort (100%) had a tight fit and fill ratio (>0.8) at the proximal level and at each follow-up. "Champagne-flute" configuration provoked high distal tight-fit and fill ratio. Poor distal fit and fill ratio compared to the proximal and the mid-stem level was measurable at each follow-up (p < 0.05). Correlations between fit and fill ratio and preoperative femur configurations were detectable.
CONCLUSIONS: Implanting the Metha prosthesis induces tight fit and fill ratio at the proximal and coated sections. Preoperative femur configuration should be considered to achieve best fit and fill situation and therefore excellent primary stability. In most cases "normal" and "stove-pipe" configurations provide good proximal fit and fill. Since "champagne-flute" configuration induces undesirable tight distal fit and fill ratio the size of the Metha (®) stem should be adequately increased to achieve a more proximal load transmission.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app