Outcomes and complications of trans-vaginal mesh repair using the Prolift™ kit for pelvic organ prolapse at 4 years median follow-up in a tertiary referral centre.
Archives of Gynecology and Obstetrics 2014 December
PURPOSE: To evaluate the anatomical, functional and post-operative outcomes of polypropylene mesh (Prolift™) in the surgical management of pelvic organ prolapse (POP).
METHODS: A single-centre observational study of 106 successive patients, who underwent Prolift™ mesh repair (POP ≥ 2) with a median follow-up of 4 years, was performed. Outcomes of interest measured included patient demographics, intra and post-operative complications, concomitant procedures for POP or urinary incontinence. Using the Baden-Walker classification, grade ≥2 prolapses in the operated compartment were deemed as surgical failure. Validated questionnaires including ICIQ-VS and ICIQ-UI were used to assess functional outcome.
RESULTS: Of the 106 patients, 56 had an anterior, 36 a posterior and 14 a total Prolift™. 101 patients were available for follow-up (median 4 years). 82 women underwent a clinical follow-up whilst 19 underwent a telephonic follow-up. Peri-operative bladder injury was noted in 2 (1.9 %) cases. Six (5.6 %) patients developed mesh exposure post-operatively. Re-operation rates for recurrent prolapse in the operated compartment were 2.8 % (n = 3). At follow-up, prolapse recurrence in the operated compartment was noted in another 7.3 % (n = 6) patients. Combining re-operations for POP and recurrences noted during follow-up, the revised failure rate was 10.1 % (n = 9). De novo prolapse in the non-operated compartment occurred in 19.5 % (n = 16) women.
CONCLUSION: Our study demonstrates that Prolift™ vaginal mesh surgery offers anatomical cure rates of 89.9 %. A higher rate of de novo recurrence in the non-operated compartment was noted suggesting that surgical correction in one compartment may exacerbate recurrence in other compartments.
METHODS: A single-centre observational study of 106 successive patients, who underwent Prolift™ mesh repair (POP ≥ 2) with a median follow-up of 4 years, was performed. Outcomes of interest measured included patient demographics, intra and post-operative complications, concomitant procedures for POP or urinary incontinence. Using the Baden-Walker classification, grade ≥2 prolapses in the operated compartment were deemed as surgical failure. Validated questionnaires including ICIQ-VS and ICIQ-UI were used to assess functional outcome.
RESULTS: Of the 106 patients, 56 had an anterior, 36 a posterior and 14 a total Prolift™. 101 patients were available for follow-up (median 4 years). 82 women underwent a clinical follow-up whilst 19 underwent a telephonic follow-up. Peri-operative bladder injury was noted in 2 (1.9 %) cases. Six (5.6 %) patients developed mesh exposure post-operatively. Re-operation rates for recurrent prolapse in the operated compartment were 2.8 % (n = 3). At follow-up, prolapse recurrence in the operated compartment was noted in another 7.3 % (n = 6) patients. Combining re-operations for POP and recurrences noted during follow-up, the revised failure rate was 10.1 % (n = 9). De novo prolapse in the non-operated compartment occurred in 19.5 % (n = 16) women.
CONCLUSION: Our study demonstrates that Prolift™ vaginal mesh surgery offers anatomical cure rates of 89.9 %. A higher rate of de novo recurrence in the non-operated compartment was noted suggesting that surgical correction in one compartment may exacerbate recurrence in other compartments.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app