Diagnostic accuracy of non-radiologist performed ultrasound for abdominal aortic aneurysm: systematic review and meta-analysis.
International Journal of Clinical Practice 2014 September
BACKGROUND: Ultrasonography is increasingly used by clinicians to identify abdominal aortic aneurysms (AAA). We performed a systematic review and meta-analysis comparing the accuracy of non-radiologist performed ultrasound (NRPUS) for AAA disease to the 'gold standard' of radiologist performed aortic imaging (RPI), intra-operative findings or postmortem findings.
METHODS: Cochrane Library, MEDLINE, EMBASE, SCOPUS-V.4, trial registries, conference proceedings, and article reference lists were searched to identify studies comparing NRPUS with RPI as the reference standard. Data abstracted from eligible studies was used to generate 2 × 2 contingency tables allowing calculation of pooled sensitivity and specificity values.
RESULTS: 11 studies (944 patients) evaluated NRPUS for AAA detection. NRPUS had a pooled sensitivity of 0.975 [95% confidence interval (CI), 0.942-0.992] for AAA detection and a pooled specificity of 0.989 (95% CI, 0.979-0.995).
CONCLUSIONS: Non-radiologist performed ultrasound achieves acceptable sensitivity and specificity for both detection and measurement of AAA. There was no evidence of significant heterogeneity with respect to pooled sensitivity or specificity.
METHODS: Cochrane Library, MEDLINE, EMBASE, SCOPUS-V.4, trial registries, conference proceedings, and article reference lists were searched to identify studies comparing NRPUS with RPI as the reference standard. Data abstracted from eligible studies was used to generate 2 × 2 contingency tables allowing calculation of pooled sensitivity and specificity values.
RESULTS: 11 studies (944 patients) evaluated NRPUS for AAA detection. NRPUS had a pooled sensitivity of 0.975 [95% confidence interval (CI), 0.942-0.992] for AAA detection and a pooled specificity of 0.989 (95% CI, 0.979-0.995).
CONCLUSIONS: Non-radiologist performed ultrasound achieves acceptable sensitivity and specificity for both detection and measurement of AAA. There was no evidence of significant heterogeneity with respect to pooled sensitivity or specificity.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app