Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Localized prostate cancer detection with 18F FACBC PET/CT: comparison with MR imaging and histopathologic analysis.

Radiology 2014 March
PURPOSE: To characterize uptake of 1-amino-3-fluorine 18-fluorocyclobutane-1-carboxylic acid ((18)F FACBC) in patients with localized prostate cancer, benign prostatic hyperplasia (BPH), and normal prostate tissue and to evaluate its potential utility in delineation of intraprostatic cancers in histopathologically confirmed localized prostate cancer in comparison with magnetic resonance (MR) imaging.

MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study. Twenty-one men underwent dynamic and static abdominopelvic (18)F FACBC combined positron emission tomography (PET) and computed tomography (CT) and multiparametric (MP) 3-T endorectal MR imaging before robotic-assisted prostatectomy. PET/CT and MR images were coregistered by using pelvic bones as fiducial markers; this was followed by manual adjustments. Whole-mount histopathologic specimens were sliced with an MR-based patient-specific mold. (18)F FACBC PET standardized uptake values (SUVs) were compared with those at MR imaging and histopathologic analysis for lesion- and sector-based (20 sectors per patient) analysis. Positive and negative predictive values for each modality were estimated by using generalized estimating equations with logit link function and working independence correlation structure.

RESULTS: (18)F FACBC tumor uptake was rapid but reversible. It peaked 3.6 minutes after injection and reached a relative plateau at 15-20 minutes (SUVmax[15-20min]). Mean prostate tumor SUVmax(15-20min) was significantly higher than that of the normal prostate (4.5 ± 0.5 vs 2.7 ± 0.5) (P < .001); however, it was not significantly different from that of BPH (4.3 ± 0.6) (P = .27). Sector-based comparison with histopathologic analysis, including all tumors, revealed sensitivity and specificity of 67% and 66%, respectively, for (18)F FACBC PET/CT and 73% and 79%, respectively, for T2-weighted MR imaging. (18)F FACBC PET/CT and MP MR imaging were used to localize dominant tumors (sensitivity of 90% for both). Combined (18)F FACBC and MR imaging yielded positive predictive value of 82% for tumor localization, which was higher than that with either modality alone (P < .001).

CONCLUSION: (18)F FACBC PET/CT shows higher uptake in intraprostatic tumor foci than in normal prostate tissue; however, (18)F FACBC uptake in tumors is similar to that in BPH nodules. Thus, it is not specific for prostate cancer. Nevertheless, combined (18)F FACBC PET/CT and T2-weighted MR imaging enable more accurate localization of prostate cancer lesions than either modality alone.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app