An assessment of 25-hydroxyvitamin D measurements in comparability studies conducted by the Vitamin D Metabolites Quality Assurance Program.
Clinica Chimica Acta; International Journal of Clinical Chemistry 2013 November 16
BACKGROUND: The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements, established the first accuracy-based program for improving the comparability of vitamin D metabolite measurements, the Vitamin D Metabolites Quality Assurance Program.
METHODS: The study samples were human serum or plasma Standard Reference Materials (SRMs) with 25-hydroxyvitamin D values that were determined at NIST. Participants evaluated the materials using immunoassay (IA), liquid chromatography (LC) with mass spectrometric detection, and LC with ultraviolet absorbance detection. NIST evaluated the results for concordance within the participant community as well as trueness relative to the NIST value.
RESULTS: For the study materials that contain mostly 25-hydroxyvitamin D3 (25(OH)D3),the coefficient of variation (CV) for the participant results was consistently in the range from 7% to 19%, and the median values were biased high relative to the NIST values. However, for materials that contain significant concentrations of both 25-hydroxyvitamin D2 (25(OH)D2) and 25(OH)D3, the median IA results were biased lower than both the LC and the NIST values, and the CV was as high as 28%. The first interlaboratory comparison results for SRM 972a Vitamin D Metabolites in Human Serum are also reported.
CONCLUSIONS: Relatively large within-lab and between-lab variability hinders conclusive assessments of bias and accuracy.
METHODS: The study samples were human serum or plasma Standard Reference Materials (SRMs) with 25-hydroxyvitamin D values that were determined at NIST. Participants evaluated the materials using immunoassay (IA), liquid chromatography (LC) with mass spectrometric detection, and LC with ultraviolet absorbance detection. NIST evaluated the results for concordance within the participant community as well as trueness relative to the NIST value.
RESULTS: For the study materials that contain mostly 25-hydroxyvitamin D3 (25(OH)D3),the coefficient of variation (CV) for the participant results was consistently in the range from 7% to 19%, and the median values were biased high relative to the NIST values. However, for materials that contain significant concentrations of both 25-hydroxyvitamin D2 (25(OH)D2) and 25(OH)D3, the median IA results were biased lower than both the LC and the NIST values, and the CV was as high as 28%. The first interlaboratory comparison results for SRM 972a Vitamin D Metabolites in Human Serum are also reported.
CONCLUSIONS: Relatively large within-lab and between-lab variability hinders conclusive assessments of bias and accuracy.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app