Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Improvement of the SNR and resolution of susceptibility-weighted venography by model-based multi-echo denoising.

NeuroImage 2013 April 16
The vein structures of the brain are important for understanding brain function and structure, especially when functional magnetic resonance imaging (fMRI) is utilized, as fMRI is based on changes in the blood-oxygen-level-dependent (BOLD) signal, which is directly related to veins. The aim of the present study was to develop an effective method to produce high signal-to-noise-ratio (SNR) and high-resolution multi-contrast susceptibility-weighted (SW) images of vein structures from 3T magnetic resonance (MR) scanners using multi-gradient-echo MR acquisition and a successive denoising process for both magnitude and phase data. Successive multi-echo MR images were acquired at multiple time points using a multigradient-recalled echo sequence at 3T, and noise in the magnitude and phase data was effectively suppressed using model-based denoising methods. A T(2)* relaxation model was used to denoise the magnitude data and a linear phase model was used to denoise the phase data. SW venography images were obtained from the denoised MR data and compared with conventional SW venography. To evaluate the performance of our denoising methods, we conducted numerical simulation studies and compared the mean-squared-error (MSE), SNR, and contrast-to-noise ratio (CNR) that we obtained using our procedure with those obtained using conventional denoising methods. In addition, images were inspected visually. Numerical simulations showed that our proposed model-based denoising methods were the most effective at suppressing noise. In vivo experiments also showed a substantial increase in the SNR of the phase mask obtained using the proposed denoising process (twice that of the conventional GRE-based phase mask). The T(2)* relaxation model method improved the SNR of the magnitude image (1.17-1.35 times that of the GRE-based magnitude image). Noise suppression of both magnitude and phase data using our proposed method resulted in an overall increase in the SNR and CNR in the final SW venography (1.1-1.5-fold and 1.96-fold higher SNR and CNR, respectively, than that of the GRE-based SW venography). We demonstrated that high SNR and high-resolution SW venograms can be obtained using multi-echo gradient-recalled acquisition and successive model-based denoising of both magnitude and phase data.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app