Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Comparison of cranial facet joint violation rates between open and percutaneous pedicle screw placement using intraoperative 3-D CT (O-arm) computer navigation.

Spine 2013 Februrary 16
STUDY DESIGN: Retrospective study comparing cranial facet joint violation rates of open and percutaneous pedicle screws inserted using 3-dimensional image-guidance.

OBJECTIVE: To determine the rate of cranial facet joint violation in intraoperative computed tomography (CT) image-guided lumbar pedicle screw instrumentation and compare facet joint violation rates between CT image-guided open and percutaneous techniques.

SUMMARY OF BACKGROUND DATA: Facet joint violation by pedicle screws can potentially result in a higher rate of adjacent segment degeneration. Reported cranial facet joint violation rates range from 7% to 100%. Intraoperative image-guidance, which has enhanced pedicle screw placement accuracy, may aid in avoiding impingement of the cranial facet joints.

METHODS: We reviewed 188 cases of 3-dimensional image-guided lumbar pedicle screw instrumentation from November 2006 to December 2011. The cranial screws of each construct were graded by 3 reviewers according to the Seo classification (0 = no impingement; 1 = screw head in contact/suspected to be in contact with joint; 2 = screw clearly invaded the joint) on intraoperative axial CT images. If there was a difference in evaluation, a consensus was reached to arrive at a single grade. The χ2 test was used to determine significance between the open and percutaneous group (α = 0.05).

RESULTS: A total of 370 screws (245 open, 125 percutaneous) were graded. Overall facet joint violation rate was 18.9% (grade 1 = 16.2%, grade 2 = 2.7%). Open technique (grade 1 = 22.4%, grade 2 = 4.1%) had a significantly higher violation rate than percutaneous technique (grade 1 = 4%, grade 2 = 0%) (P < 0.0001). There is a trend of an increasing likelihood of facet joint violation from L1 to L5.

CONCLUSION: The use of intraoperative CT image-guidance in lumbar pedicle screw placement resulted in a facet joint violation rate at the lower end of the reported range in literature. The percutaneous technique has a significantly lower facet violation rate than the open technique.

LEVEL OF EVIDENCE: 4.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app