Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Reliability of six physical performance tests in older people with dementia.

Physical Therapy 2013 January
BACKGROUND: Physical performance tests are important for assessing the effect of physical activity interventions in older people with dementia, but their psychometric properties have not been systematically established within this specific population.

OBJECTIVE: The purpose of this study was to determine the relative and absolute test-retest reliability of the 6-m walk test, the figure-of-Eight Walk Test (F8W), the Timed "Up & Go" Test (TUG), the Frailty and Injuries: Cooperative Studies of Intervention Techniques-4 (FICSIT-4) Balance Test, the Chair Rise Test (CRT), and the Jamar dynamometer. These tests are used to assess gait speed, dynamic balance, functional mobility, static balance, lower-limb strength, and grip strength, respectively.

DESIGN: This investigation was a prospective, nonexperimental study.

METHODS: Older people with dementia (n=58, age range=70-92 years) performed each test at baseline and again after 1 week. Intraclass correlation coefficients (ICC), standard error of measurement (SEM), minimal detectable change (MDC), and log-transferred limits of agreement of Bland-Altman plots were calculated.

RESULTS: The relative reliability of the F8W, TUG, and Jamar dynamometer was excellent (ICC=.90-.95) and good for the 6-m walk test, FICSIT-4, and CRT (ICC=.79-.86). The SEMs and MDCs were large for all tests. The absolute reliability of the TUG and CRT was significantly influenced by the level of cognitive functioning (as assessed with the Mini-Mental State Examination [MMSE]).

LIMITATIONS: The specific etiology of dementia was not obtained.

CONCLUSIONS: The physical performance tests evaluated are useful for detecting differences in performance between older people with mild to moderate dementia and, therefore, are suitable for cross-sectional or controlled intervention studies. They appear less suitable to monitor clinically relevant intra-individual performance changes. Future studies should focus on the development of more sensitive tests and the identification of criteria for clinically relevant changes in this rapidly growing population.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app