British Journal of Anaesthesia 2011 August
BACKGROUND: We aimed at comparing the performance of the C-MAC®, Airtraq®, and Macintosh laryngoscopes when performing tracheal intubation in patients undergoing neck immobilization using manual inline axial cervical spine stabilization.
METHODS: Ninety consenting patients presenting for surgery requiring tracheal intubation were randomly assigned to undergo intubation using a C-MAC® (n=30), Airtraq® (n=29), or Macintosh (n=31) laryngoscope. All patients were intubated by one anaesthetist experienced in the use of each laryngoscope.
RESULTS: The Airtraq® laryngoscope performed best in these patients, reducing the Intubation Difficulty Scale score, improving the Cormack and Lehane glottic view, and reducing the need for optimization manoeuvres, compared with both the Macintosh and the C-MAC®. The C-MAC® and Macintosh laryngoscopes performed similarly. There were no differences in success rates or haemodynamic profiles post-intubation between any of the devices tested.
CONCLUSIONS: The Airtraq® laryngoscope performed better than the C-MAC® and Macintosh laryngoscopes in patients undergoing cervical immobilization.
METHODS: Ninety consenting patients presenting for surgery requiring tracheal intubation were randomly assigned to undergo intubation using a C-MAC® (n=30), Airtraq® (n=29), or Macintosh (n=31) laryngoscope. All patients were intubated by one anaesthetist experienced in the use of each laryngoscope.
RESULTS: The Airtraq® laryngoscope performed best in these patients, reducing the Intubation Difficulty Scale score, improving the Cormack and Lehane glottic view, and reducing the need for optimization manoeuvres, compared with both the Macintosh and the C-MAC®. The C-MAC® and Macintosh laryngoscopes performed similarly. There were no differences in success rates or haemodynamic profiles post-intubation between any of the devices tested.
CONCLUSIONS: The Airtraq® laryngoscope performed better than the C-MAC® and Macintosh laryngoscopes in patients undergoing cervical immobilization.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app