Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Diagnostic accuracy of urine dipsticks for detection of albuminuria in the general community.

BACKGROUND: Urine dipsticks, an inexpensive accessible test for proteinuria, are widely advocated for mass screening; however, their diagnostic accuracy in the general community is largely unknown.

STUDY DESIGN: Evaluation of diagnostic test accuracy in a cross-sectional cohort.

SETTING & PARTICIPANTS: AusDiab, a representative survey of Australian adults 25 years and older (conducted in 1999/2000). Stratified cluster random sampling from 11,247 individuals participating in the biomedical examination; complete urinalysis data available for 10,944.

INDEX TEST: Urine dipsticks (Bayer Multistix), with a positive result defined as ≥1+ or trace or higher protein.

REFERENCE TEST: Albumin-creatinine ratio (ACR), measured on a random spot urine sample. Reference test positivity was defined as ACR ≥30 mg/g or ACR ≥300 mg/g.

RESULTS: Numbers of participants with ACR <30, 30-300, and ≥300 mg/g were 10,219 (93.4%), 634 (5.8%), and 91 (0.8%), respectively. The area under the receiver operating characteristic curve (AUC) for dipstick detection of ACR ≥30 mg/g was 0.8451 ± 0.0129 (SE) in men and 0.7775 ± 0.0131 in women (P < 0.001). The AUROC for dipstick detection of ACR ≥300 mg/g was 0.9904 ± 0.0030 in men and 0.9950 ± 0.0016 in women (P = 0.02). Dipstick result ≥1+ identified ACR ≥30 mg/g with 57.8% sensitivity (95% CI, 54.1%-61.4%) and 95.4% specificity (95% CI, 95.0%-95.8%) and identified ACR ≥300 mg/g with 98.9% sensitivity (99% CI, 92.1%-100%) and 92.6% specificity (99% CI, 92.0%-93.3%). A dipstick result of trace or higher identified ACR ≥30 mg/g with 69.4% sensitivity (95% CI, 65.9%-72.7%) and 86.8% specificity (95% CI, 86.1%-87.4%) and identified ACR ≥300 mg/g with 100% sensitivity (99% CI, 94.3%-100%) and 83.7% specificity (99% CI, 82.8%-84.6%). A negative dipstick result (less than trace) had a negative predictive value of 97.6% (95% CI, 97.2%-97.9%) for ACR ≥30 mg/g and a negative predictive value of 100% (99% CI, 99.9%-100%) for ACR ≥300 mg/g. The probability of an ACR ≥30 mg/g confirmed on laboratory investigation was 47.2% (95% CI, 43.9%-50.5%) based on a dipstick result ≥1+ and 27.1% (95% CI, 25.1%-29.2%) based on a trace or higher result.

LIMITATIONS: Isolated urine samples precluded assessment of test reproducibility. Urine specific gravity and pH were not recorded; therefore, the effect of urine concentration on test performance was not assessed.

CONCLUSIONS: A dipstick test result <1+ or less than trace has a high negative predictive value in the general community setting, with minimal risk of a missed diagnosis of macroalbuminuria. High false-positive rates emphasize the need for laboratory confirmation of positive results.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app