Journal Article
Research Support, N.I.H., Extramural
Research Support, U.S. Gov't, Non-P.H.S.
Validation Studies
Add like
Add dislike
Add to saved papers

In vitro and preliminary in vivo validation of echo particle image velocimetry in carotid vascular imaging.

Noninvasive, easy-to-use and accurate measurements of wall shear stress (WSS) in human blood vessels have always been challenging in clinical applications. Echo particle image velocimetry (Echo PIV) has shown promise for clinical measurements of local hemodynamics and wall shear rate. Thus far, however, the method has only been validated under simple flow conditions. In this study, we validated Echo PIV under in vitro and in vivo conditions. For in vitro validation, we used an anatomically correct, compliant carotid bifurcation flow phantom with pulsatile flow conditions, using optical particle image velocimetry (optical PIV) as the reference standard. For in vivo validation, we compared Echo PIV-derived 2-D velocity fields obtained at the carotid bifurcation in five normal subjects against phase-contrast magnetic resonance imaging (PC-MRI)-derived velocity measurements obtained at the same locations. For both studies, time-dependent, 2-D, two-component velocity vectors; peak/centerline velocity, flow rate and wall shear rate (WSR) waveforms at the common carotid artery (CCA), carotid bifurcation and distal internal carotid artery (ICA) were examined. Linear regression, correlation analysis and Bland-Altman analysis were used to quantify the agreement of different waveforms measured by the two techniques. In vitro results showed that Echo PIV produced good images of time-dependent velocity vector maps over the cardiac cycle with excellent temporal (up to 0.7 ms) and spatial (∼0.5 mm) resolutions and quality, comparable with optical PIV results. Further, good agreement was found between Echo PIV and optical PIV results for velocity and WSR measurements. In vivo results also showed good agreement between Echo PIV velocities and phase contrast MRI velocities. We conclude that Echo PIV provides accurate velocity vector and WSR measurements in the carotid bifurcation and has significant potential as a clinical tool for cardiovascular hemodynamics evaluation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app