A higher chest compression rate may be necessary for metronome-guided cardiopulmonary resuscitation.
American Journal of Emergency Medicine 2012 January
OBJECTIVES: Metronome guidance is a simple and economical feedback system for guiding cardiopulmonary resuscitation (CPR). However, a recent study showed that metronome guidance reduced the depth of chest compression. The results of previous studies suggest that a higher chest compression rate is associated with a better CPR outcome as compared with a lower chest compression rate, irrespective of metronome use. Based on this finding, we hypothesized that a lower chest compression rate promotes a reduction in chest compression depth in the recent study rather than metronome use itself.
METHODS: One minute of chest compression-only CPR was performed following the metronome sound played at 1 of 4 different rates: 80, 100, 120, and 140 ticks/min. Average compression depths (ACDs) and duty cycles were compared using repeated measures analysis of variance, and the values in the absence and presence of metronome guidance were compared.
RESULTS: Both the ACD and duty cycle increased when the metronome rate increased (P = .017, <.001). Average compression depths for the CPR procedures following the metronome rates of 80 and 100 ticks/min were significantly lower than those for the procedures without metronome guidance.
CONCLUSIONS: The ACD and duty cyle for chest compression increase as the metronome rate increases during metronome-guided CPR. A higher rate of chest compression is necessary for metronome-guided CPR to prevent suboptimal quality of chest compression.
METHODS: One minute of chest compression-only CPR was performed following the metronome sound played at 1 of 4 different rates: 80, 100, 120, and 140 ticks/min. Average compression depths (ACDs) and duty cycles were compared using repeated measures analysis of variance, and the values in the absence and presence of metronome guidance were compared.
RESULTS: Both the ACD and duty cycle increased when the metronome rate increased (P = .017, <.001). Average compression depths for the CPR procedures following the metronome rates of 80 and 100 ticks/min were significantly lower than those for the procedures without metronome guidance.
CONCLUSIONS: The ACD and duty cyle for chest compression increase as the metronome rate increases during metronome-guided CPR. A higher rate of chest compression is necessary for metronome-guided CPR to prevent suboptimal quality of chest compression.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app