Journal Article
Randomized Controlled Trial
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Effect of an electronic nicotine delivery device (e cigarette) on desire to smoke and withdrawal, user preferences and nicotine delivery: randomised cross-over trial.

Tobacco Control 2010 April
OBJECTIVES: To measure the short-term effects of an electronic nicotine delivery device ("e cigarette", ENDD) on desire to smoke, withdrawal symptoms, acceptability, pharmacokinetic properties and adverse effects.

DESIGN: Single blind randomised repeated measures cross-over trial of the Ruyan V8 ENDD.

SETTING: University research centre in Auckland, New Zealand.

PARTICIPANTS: 40 adult dependent smokers of 10 or more cigarettes per day.

INTERVENTIONS: Participants were randomised to use ENDDs containing 16 mg nicotine or 0 mg capsules, Nicorette nicotine inhalator or their usual cigarette on each of four study days 3 days apart, with overnight smoking abstinence before use of each product.

MAIN OUTCOME MEASURES: The primary outcome was change in desire to smoke, measured as "area under the curve" on an 11-point visual analogue scale before and at intervals over 1 h of use. Secondary outcomes included withdrawal symptoms, acceptability and adverse events. In nine participants, serum nicotine levels were also measured.

RESULTS: Over 60 min, participants using 16 mg ENDD recorded 0.82 units less desire to smoke than the placebo ENDD (p=0.006). No difference in desire to smoke was found between 16 mg ENDD and inhalator. ENDDs were more pleasant to use than inhalator (p=0.016) and produced less irritation of mouth and throat (p<0.001). On average, the ENDD increased serum nicotine to a peak of 1.3 mg/ml in 19.6 min, the inhalator to 2.1 ng/ml in 32 min and cigarettes to 13.4 ng/ml in 14.3 min.

CONCLUSIONS: The 16 mg Ruyan V8 ENDD alleviated desire to smoke after overnight abstinence, was well tolerated and had a pharmacokinetic profile more like the Nicorette inhalator than a tobacco cigarette. Evaluation of the ENDD for longer-term safety, potential for long-term use and efficacy as a cessation aid is needed. Trial registration No.12607000587404, Australia and New Zealand Clinical Trials Register.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app