OPEN IN READ APP
JOURNAL ARTICLE

The clinical feasibility and effect of online cone beam computer tomography-guided intensity-modulated radiotherapy for nasopharyngeal cancer

Jin Wang, Sen Bai, Nianyong Chen, Feng Xu, Xiaoqin Jiang, Yan Li, Qingfeng Xu, Yali Shen, Hong Zhang, Youling Gong, Renming Zhong, Qingfeng Jiang
Radiotherapy and Oncology 2009, 90 (2): 221-7
18930327

BACKGROUND AND PURPOSE: Online adaptive correction in image-guided intensity-modulated radiotherapy appeared to be a promising approach for precision radiation treatment in head and neck tumors. This protocol was designed to evaluate the clinical feasibility and effect of online cone beam computed tomography (CBCT) guidance in IMRT of nasopharyngeal cancer (NPC).

METHODS AND MATERIALS: The Elekta Synergy system, which integrates an X-ray volumetric imager (XVI), was used to deliver radiation treatment for 22 cases of NPC. The acquired CBCT was registered to the planning CT for online and offline analysis. The systematic and random setup errors, as well as planning target volume (PTV) margin, were calculated at different correction threshold levels. The impact of online setup correction on dosimetry was evaluated by simulation of pre-correction errors.

RESULTS: The correction-of-setup-errors frequencies for 1, 2 and 3mm thresholds were 41.3-53.9%, 12.7-21.2% and 6.3-10.3%, respectively. Online correction was effective at the 2mm threshold level for all three axes. The pre-correction systematic errors for the whole group ranged 1.1-1.3mm, and the random errors were also 1.1-1.3mm. After online correction, the systematic and random errors ranged 0.4-0.5mm and 0.7-0.8mm, respectively, in the three directions. The PTV margins for the pre-correction, pretreatment and post-treatment positions were 3.5-4.2mm, 1.6-1.8mm and 2.5-3.2mm, respectively, in three directions. Analysis of hypothetical dosimetric change due to a translational isocenter shift of 3mm showed that if no correction was applied, the mean maximum dose to both the brain stem and spinal cord would be increased by 10Gy, the mean dose to the left and right parotids would be increased by 7.8 and 8.5Gy, respectively, and the dose to target volumes would be decreased: 4Gy for 95% GTV and 5.6Gy for 95% CTV(60.)

CONCLUSIONS: CBCT-based online correction increased the accuracy of IMRT for NPC and reduced irradiated margins, by decreasing both the systematic and random errors. Online CBCT correction reduces the radiation dose to normal tissue and creates room for further dose escalation of tumors.

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
18930327
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"