Clinical Trial
Journal Article
Validation Studies
Add like
Add dislike
Add to saved papers

The use of magnetic sensors to monitor moderate deep inspiration breath hold during breast irradiation with dynamic MLC compensators.

BACKGROUND AND PURPOSE: To reduce the dose to the heart during left breast irradiation, a moderate deep breath hold technique (MDIBH) was introduced. Originally, verification of the MDIBH was performed with portal images acquired in movie loop during the treatment delivery. However, this verification method is not compatible with the use of dynamic MLC compensation, recently introduced because of its often superior dose distribution. Magnetic sensors were evaluated as an additional/alternative method to monitor the breath hold.

MATERIAL AND METHODS: In a first phase, the reproducibility of MDIBH for breast patients was evaluated by investigating for 19 patients the set-up errors derived from portal images in cine loop acquisition during MDIBH. In a second phase, for 10 patients, the breathing curves recorded by magnetic sensors were used to monitor beam-on and beam-off while portal images were simultaneously recorded in movie loop. In a third phase, breast patients treated with dynamic MLC compensation were trained for MDIBH and monitored with magnetic sensors.

RESULTS: The interfraction reproducibility of MDIBH for the initial 19 patients was recorded: the mean set-up error, the systematic and the random deviations are all smaller than 4mm in the anterior-posterior direction and in the cranio-caudal direction and smaller than 2 degrees along the rotation axis. Magnetic sensors provided a reproducible breathing curve: while the mean amplitude recorded for 10 patients varied substantially between patients, the individual standard deviation of the amplitude for each session was smaller than 3mm. For these 10 patients, the intrafraction set-up variation between the first portal image of two consecutive breath holds and the intra-breath hold set-up variation between the first and last portal image of each breath hold is smaller than 2mm in the anterior-posterior direction, smaller than 3mm in the cranio-caudal direction and smaller than 1.5 degrees along the rotation axis.

CONCLUSION: Using magnetic sensors to record the breathing curve of left breast patients in MDIBH, a verification method was developed, suitable for combining MDIBH with dynamic MLC compensation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app